Customization: | Available |
---|---|
After-sales Service: | 7 X 24 Hours |
Warranty: | 15 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
A cooling air chiller, also known as a cold water machine or air-cooled chiller, is a device used to remove heat from a process or equipment by circulating chilled air. It consists of a compressor, condenser, evaporator, and a fan. The process begins with the compressor compressing a refrigerant gas, which increases its temperature and pressure. The hot gas then flows to the condenser where it releases heat to the ambient air and condenses into a liquid.
The liquid refrigerant then moves to the evaporator where it undergoes a phase change, absorbing heat from the process or equipment that needs to be cooled. The chilled air produced by the evaporator is circulated using a fan and directed towards the target area or equipment. The warm refrigerant gas then returns to the compressor to complete the cycle.
A cooling air chiller is commonly used in industrial applications, including film blowing machines, injection molding machines, printing presses, laser cutting machines, and various other processes and equipment that generate heat during operation. It helps maintain optimal operating temperatures and prevents overheating, ensuring efficient and stable performance of the equipment.
A cold water chiller, also known as a water chiller or water-cooled chiller, is a mechanical refrigeration device used to cool water to a desired temperature. It is commonly used in industrial and commercial applications to provide cooling for various processes, equipment, and environments.
The basic principle of a cold water chiller involves the circulation of chilled water through a closed-loop system. The chiller consists of key components such as a compressor, condenser, evaporator, expansion valve, and a water circulation pump.
Here's a brief overview of how a cold water chiller works:
Compression: The compressor in the chiller pressurizes a refrigerant gas, typically a type of refrigerant such as R-134a or R-410a, which increases its temperature.
Condensation: The high-pressure, high-temperature refrigerant gas flows into the condenser, where it releases heat to the surrounding air or a separate cooling medium, such as a cooling tower. As a result, the refrigerant condenses into a high-pressure liquid.
Expansion: The high-pressure liquid refrigerant passes through the expansion valve, which reduces its pressure and subsequently its temperature. This causes the refrigerant to change into a low-pressure, low-temperature mixture of liquid and vapor.
Evaporation: The low-pressure refrigerant enters the evaporator, which is a heat exchanger. Here, it absorbs heat from the water circulating through the evaporator, causing the refrigerant to evaporate and return to its gaseous state. This heat absorption process cools down the water.
Circulation: A water circulation pump moves the chilled water from the evaporator to the application or process that requires cooling, such as air conditioning systems, industrial processes, or data centers. The heated water is then returned to the chiller for recooling.
The cycle repeats as long as the chiller is operational, maintaining a constant flow of chilled water to meet the cooling requirements.
More Pictures of the small air cooled Water Chiller : Model Item |
OMC-1A | OMC-2A | OMC-3A | OMC-5A | OMC-8A | OMC-10A | OMC-15A | OMC-20A | OMC-25A | OMC-30A | OMC-40A | ||
Cooling Capacity | KW | 2.7 | 5.4 | 8.1 | 13.5 | 21.6 | 27 | 40.5 | 54 | 67.5 | 81 | 108 | |
Kcal/h | 2322 | 4644 | 6966 | 11610 | 18576 | 23220 | 34830 | 46440 | 58050 | 69660 | 92880 | ||
Ton | 0.8 | 1.5 | 2.3 | 3.8 | 6.1 | 7.7 | 11.5 | 15.4 | 19.2 | 23.0 | 30.7 | ||
Btu/h | 9215 | 18430 | 27645 | 46075 | 73720 | 92150 | 138225 | 184300 | 230375 | 276451 | 368601 | ||
Input Power | KW | 1.4 | 2.1 | 2.8 | 5 | 7.3 | 9.2 | 14 | 18 | 22 | 28 | 36 | |
Power supply | 1PH-220V 50Hz | 3PH-380V 50Hz | |||||||||||
Temperature Range | ºC | 5-35 | |||||||||||
Refrigerant | Type | R22(R407C/R410A/R134A) | |||||||||||
Compressor | Control Mode | Capillary | Expansion Valve | ||||||||||
Type | Piston Type / Scroll Type | ||||||||||||
Power | KW | 0.75 | 1.5 | 2.2 | 4 | 6 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | |
Chilled water | Tank Volume | L | 25 | 30 | 60 | 65 | 150 | 180 | 300 | 400 | 400 | 540 | 630 |
Tank Material | SUS304 Stainless Steel | ||||||||||||
Pipe Diameter | inch | 1/2 | 3/4 | 3/4 | 1 | 1-1/2 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | |
Pump | Lift | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | |
Power | 0.37 | 0.37 | 0.37 | 0.75 | 1.1 | 1.5 | 1.5 | 2.2 | 2.2 | 4 | 4 | ||
Evaporator | Type | Tank with coil(Shell and Tube) | |||||||||||
Chilled Water Flow | m³/h | 0.5 | 0.9 | 1.4 | 2.3 | 3.7 | 4.6 | 7.0 | 9.3 | 11.6 | 13.9 | 18.6 | |
Condenser | Type | High efficiency copper condensing coil with Aluminum+Spiral axial flow fan | |||||||||||
Cooling Air Flow | m³/h | 1000 | 2000 | 3000 | 5000 | 8000 | 10000 | 15000 | 20000 | 25000 | 30000 | 40000 | |
Safety Protection | Compressor overheating protection, over-current protection, high and low pressure protection, over-temperature protection, flow protection, reversed and lacking phase protection, exhaust overheating protection. | ||||||||||||
Dimension | Length | mm | 680 | 770 | 1000 | 1120 | 1250 | 1500 | 2080 | 2100 | 2100 | 2300 | 2430 |
Width | mm | 420 | 500 | 480 | 530 | 680 | 770 | 780 | 850 | 850 | 930 | 1185 | |
Height | mm | 850 | 950 | 1100 | 1200 | 1350 | 1400 | 1650 | 1600 | 1700 | 1650 | 1710 | |
Weight | KG | 73 | 95 | 128 | 172 | 300 | 350 | 750 | 850 | 950 | 1080 | 1360 |
Air-cooled chiller is a common industrial cooling equipment with the following advantages:
Independent cooling system: The air-cooled chiller adopts an independent air cooling system and does not require additional cooling water sources or cooling towers. This makes installation and operation relatively simple, saving installation and maintenance costs and space.
Wide range of applications: Air-cooled chillers are suitable for various industrial applications, including plastic processing, refrigeration and air conditioning systems, machining, printing and paper making. They provide reliable cooling for different equipment and processes.
High efficiency and energy saving: The air-cooled chiller adopts air cooling method and uses forced fans to circulate the air and take away the heat. Compared to traditional water-cooled systems, they do not require additional water pumps and cooling towers, thus saving energy and operating costs.
Flexibility and mobility: Since they do not need to be connected to an external cooling water source, air-cooled chillers are more flexible and can be moved to different locations more easily. This is useful for applications that require movement or changes in work location.
Easy maintenance: Compared with water cooling systems, air-cooled chillers are easier to maintain. There is no need to deal with problems such as scale, water treatment and water pump maintenance, reducing the complexity and cost of maintenance work.
Small footprint: Air-cooled chillers have a relatively small footprint as they do not require a cooling tower and water cooling system. This is very advantageous when space is limited.
However, it should be noted that air-cooled chillers may be slightly less efficient than water-cooled systems in heat dissipation efficiency, especially in high-temperature environments. In addition, since air cooling requires the use of fans, noise and vibration may occur. Therefore, when selecting cooling equipment, it is necessary to comprehensively consider the advantages and disadvantages based on specific needs and process requirements, and weigh various factors.
Q1: Could you help us to recommend the model for our project?
A1: Yes, we have engineer to check the details and make the scheme for you. Based on the following:
1)Cooling capacity;
2)chilled water inlet and outlet temperature
3)chilled water flow
4) Refrigerant;
5) Ambient temperature;
6)Voltage;
7) Be used for what industry?
8)Any other special requirements
Q2: How to ensure your product with good quality?
A2: All our products with CE certificate. And use the well-know brand compressors and refrigeration accessories . All OUMAL Chillers are factory tested under load conditions to ensure good quality and easy installation for users.
Q3: What's the warranty?
A3: 15 months warranty for free if confirmed by both side damage in the quality reason.
Q4: What's your payment term?
A4: We accept T/T, LC, Western Union, etc. Normally, 30% deposit for production, 70% balance before shipment.
Q5: Are you a manufacturer?
A5: Yes, we have more than 15 years in water chiller business. Also have patent on the water chiller appearance .
The control box design make the unit safety and stably.
Q6: How can i Place an order
A6: Send inquiry to us or Call us.