After-sales Service: 7 X 24 Hours
Warranty: 15 Months
Type: Air-Cooled
Cooling Method: Air-cooled
Unit Structure: Integral
Selected Voltage: 50Hz/60Hz Inverter
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (15)

Basic Info.

Model NO.
OMC-8A
Compressor Number
1
Noise Level
Low
Application Fields
Electroplating
Application Machine
CNC Machine Tools
Condition
New
Refrigerant
R410A
Cooling Capacity
20kw
Compressor Type
Scroll Type
Delivery Time
15-20 Working Days
Evaporator Type
Tank with Coil / Shell and Tube
Transport Package
Plywood Package
Specification
8HP
Trademark
OUMAL
Origin
China
HS Code
8418692090
Production Capacity
5000

Product Description

5 Ton Air Cooled Scroll Chiller with Special Anti-Corrosion Treatment Cooling Electroplating Acid Tank

A water cooling system for electroplating is a specialized system designed to cool down the electroplating tank and maintain a stable temperature during the electroplating process. It typically consists of the following components:

  1. Chiller: The chiller is the main component of the water cooling system. It circulates chilled water to remove heat from the electroplating tank. The chiller uses a refrigeration cycle to cool the water and maintain the desired temperature.

  2. Heat Exchanger: A heat exchanger is used to transfer the heat from the water in the electroplating tank to the chilled water from the chiller. It helps maintain the proper temperature of the electroplating solution.

  3. Circulation Pump: The circulation pump helps circulate the chilled water from the chiller through the heat exchanger and back to the electroplating tank. It ensures a continuous flow of cooled water to maintain consistent temperature control.

  4. Temperature Controller: A temperature controller is used to monitor and control the temperature of the water in the electroplating tank. It helps maintain the desired temperature range for optimal electroplating results.

  5. Piping and Valves: Piping and valves are used to connect the chiller, heat exchanger, and electroplating tank, allowing the flow of chilled water to and from the tank.

The water cooling system for electroplating is crucial for controlling the temperature of the electroplating solution. It helps prevent overheating or temperature fluctuations, ensuring the quality and consistency of the electroplated products. By removing excess heat generated during the electroplating process, it improves the efficiency of the plating operation and extends the life of the plating solution.

5 Ton Air Cooled Scroll Chiller with Special Anti-Corrosion Treatment Cooling Electroplating Acid TankMain features of electroplating chiller
1. No need to install a cooling tower, easy to install and move, suitable for situations where water sources are scarce and no need to install a water tower;
2. Low-noise fan motor, excellent cooling and condensation effect, stable throttling mechanism, excellent anti-rust treatment;
3. Upgrade the heat exchanger made of titanium material to meet the corrosion requirements of the electroplating industry;
4. Install anti-corrosion evaporators, stainless steel pipes, stainless steel pumps or use plate exchangers. It will help stabilize metal ions and make them
Quickly attach electroplated parts, which not only increases density and smoothness, but also reduces the number of electroplating times, improves productivity, and helps to quickly recycle various chemicals
products and reduce waste;
5. Upgraded pure stainless steel water tank without coil, with long-lasting and stable cooling effect, and temperature control accuracy of ±1ºC;
6. Add ultra-high and low temperature display and signal output protection, and configure normally open and normally closed outputs for selection;
7. The upgraded chilled water circulation system adopts stainless steel multi-stage pumps and stainless steel and PVC material connections. There is no worry about rust. Pure water can be used directly or purified water can be used directly.
ionized water;
8. Add a water filter to provide the precision of high-quality laser work, add a water outlet pressure display meter to facilitate the adjustment of pressure and flow, and increase the belt flow.
The power protection device automatically cuts off the power of the laser machine when the water flow is too low to prevent the laser head from overheating due to lack of water. It also adds electronic temperature control and double-digit display.
It has a variety of settings and fault display functions. It only requires one button operation (on/off key), and the other functions are automatically realized by the memory function;
9. The cooling capacity range is: 102500Kcal/h to 654800Kcal/h.
10. The unit does not need to be equipped with cooling water pumps, cooling towers and other auxiliary equipment. It can be used as long as it is in a well-ventilated place, which can save a lot of materials.
and engineering installation costs, and there is no need to even set up a computer room.
11. In addition to finalized products, our company can also customize various special chillers and heat pump units according to customer requirements, and provide on-site assembly and technical support.
Guidance and on-site debugging services.
12. The condenser of the unit is of fin type, made of double oil corrugated hydrophilic aluminum platinum, and is manufactured by professional heat exchanger processing equipment. It has a compact structure and small volume.
It has the advantages of small size, light weight and high heat exchange efficiency, and is equipped with a low-speed large-leaf axial flow fan, which can effectively reduce operating noise and reduce environmental impact.
The influence of surrounding environment.

5 Ton Air Cooled Scroll Chiller with Special Anti-Corrosion Treatment Cooling Electroplating Acid TankElectroplating chiller is an anti-corrosion chiller. This anti-corrosion air-cooled chiller is mainly used in electroplating factories. It can also be used in various chiller systems for cooling acidic liquids or chiller systems for alkaline liquids.

An anti-corrosion water chiller is typically used in environments where there is a need to cool corros liquids or fluids, as in chemical processing plants, laboratories, or industrial applications involving corrosive materials. The chiller is designed with specific materials and components that are resistant to corrosion, ensuring the reliability and longevity of the cooling system.

Some key applications of anti-corrosion water chillers include:

  1. Chemical Processing: In industries where corrosive chemicals are involved, such as in the production of acids, alkalis, or other corrosive substances, an anti-corrosion water chiller is essential to maintain optimal temperatures and protect equipment from damage.

  2. Pharmaceuticals and Biotechnology: Temperature control is crucial in pharmaceutical and biotech processes. Anti-corrosion water chillers are used to cool equipment like reactors, fermenters, and storage tanks, ensuring product quality and equipment longevity.

  3. Metal Surface Treatment: Electroplating, anodizing, or other surface treatment processes require precise temperature control. Anti-corrosion chillers are capable of cooling the process baths and tanks, preventing damage to the substrates and maintaining consistent product quality.

  4. Food and Beverage Processing: In certain applications where corrosive substances are used for cleaning or sanitation purposes, an anti-corrosion water chiller can be used to cool the wash-down equipment or provide chilled water for food and beverage processing.

These are just a few examples of the applications of anti-corrosion water chillers. The specific requirements of each application may vary, but the focus is always on maintaining the integrity and efficiency of the cooling system when dealing with corrosive substances or environments.


5 Ton Air Cooled Scroll Chiller with Special Anti-Corrosion Treatment Cooling Electroplating Acid Tank
Products Specifications
                                       Model 
         Item
OMC-1A OMC-2A OMC-3A OMC-5A OMC-8A OMC-10A OMC-15A OMC-20A OMC-25A OMC-30A OMC-40A
Cooling Capacity KW 2.7 5.4 8.1 13.5 21.6 27 40.5 54 67.5 81 108
Kcal/h 2322 4644 6966 11610 18576 23220 34830 46440 58050 69660 92880
Ton 0.8  1.5  2.3  3.8  6.1  7.7  11.5  15.4  19.2  23.0  30.7 
Btu/h 9215  18430  27645  46075  73720  92150  138225  184300  230375  276451  368601 
Input Power KW 1.4 2.1 2.8 5 7.3 9.2 14 18 22 28 36
Power supply 1PH-220V  50Hz 3PH-380V  50Hz
Temperature Range ºC 5-35
Refrigerant Type   R22(R407C/R410A/R134A)
Compressor Control Mode   Capillary Expansion Valve
Type   Piston Type / Scroll Type 
Power KW 0.75 1.5 2.2 4 6 7.5 11 15 18.5 22 30
Chilled water  Tank Volume L 25 30 60 65 150 180 300 400 400 540 630
Tank Material   SUS304 Stainless Steel
Pipe Diameter inch 1/2 3/4 3/4 1 1-1/2 1-1/2 2 2 2-1/2 2-1/2 3
Pump Lift   20 20 20 20 20 20 20 20 20 20 20
Power   0.37 0.37 0.37 0.75 1.1 1.5 1.5 2.2 2.2 4 4
Evaporator Type   Tank with coil(Shell and Tube)
Chilled Water Flow m³/h 0.5  0.9  1.4  2.3  3.7  4.6  7.0  9.3  11.6  13.9  18.6 
Condenser Type   High efficiency copper condensing coil with Aluminum+Spiral axial flow fan
Cooling Air Flow m³/h 1000 2000 3000 5000 8000 10000 15000 20000 25000 30000 40000
Safety Protection Compressor overheating protection, over-current protection, high and low pressure protection, over-temperature protection, flow protection, reversed and lacking phase protection, exhaust overheating protection. 
Dimension Length mm 680 770 1000 1120 1250 1500 2080 2100 2100 2300 2430
Width mm 420 500 480 530 680 770 780 850 850 930 1185
Height mm 850 950 1100 1200 1350 1400 1650 1600 1700 1650 1710
Weight KG 73 95 128 172 300 350 750 850 950 1080 1360

Air-cooled chiller is a common industrial cooling equipment with the following advantages:

Independent cooling system: The air-cooled chiller adopts an independent air cooling system and does not require additional cooling water sources or cooling towers. This makes installation and operation relatively simple, saving installation and maintenance costs and space.

Wide range of applications: Air-cooled chillers are suitable for various industrial applications, including plastic processing, refrigeration and air conditioning systems, machining, printing and paper making. They provide reliable cooling for different equipment and processes.

High efficiency and energy saving: The air-cooled chiller adopts air cooling method and uses forced fans to circulate the air and take away the heat. Compared to traditional water-cooled systems, they do not require additional water pumps and cooling towers, thus saving energy and operating costs.

Flexibility and mobility: Since they do not need to be connected to an external cooling water source, air-cooled chillers are more flexible and can be moved to different locations more easily. This is useful for applications that require movement or changes in work location.

Easy maintenance: Compared with water cooling systems, air-cooled chillers are easier to maintain. There is no need to deal with problems such as scale, water treatment and water pump maintenance, reducing the complexity and cost of maintenance work.

Small footprint: Air-cooled chillers have a relatively small footprint as they do not require a cooling tower and water cooling system. This is very advantageous when space is limited.

However, it should be noted that air-cooled chillers may be slightly less efficient than water-cooled systems in heat dissipation efficiency, especially in high-temperature environments. In addition, since air cooling requires the use of fans, noise and vibration may occur. Therefore, when selecting cooling equipment, it is necessary to comprehensively consider the advantages and disadvantages based on specific needs and process requirements, and weigh various factors.

5 Ton Air Cooled Scroll Chiller with Special Anti-Corrosion Treatment Cooling Electroplating Acid Tank5 Ton Air Cooled Scroll Chiller with Special Anti-Corrosion Treatment Cooling Electroplating Acid Tank
FAQ:

Q1: Could you help us to recommend the model for our project?

A1: Yes, we have engineer to check the details and make the scheme for you. Based on the following:

1)Cooling capacity;

2)chilled water inlet and outlet temperature

3)chilled water flow

4) Refrigerant;

5) Ambient temperature;

6)Voltage;

7) Be used for what industry?

8)Any other special requirements

 

Q2: How to ensure your product with good quality?

A2: All our products with CE certificate. And use the well-know brand compressors and refrigeration accessories . All OUMAL Chillers are factory tested under load conditions to ensure good quality and easy installation for users.

 

Q3: What's the warranty?

A3: 15 months warranty for free if confirmed by both side damage in the quality reason.

 

Q4: What's your payment term?

A4: We accept T/T, LC, Western Union, etc. Normally, 30% deposit for production, 70% balance before shipment.

 

Q5: Are you a manufacturer?

A5: Yes, we have more than 15 years in water chiller business. Also have patent on the water chiller appearance .

The control box design make the unit safety and stably.

 

Q6: How can i Place an order

 A6: Send inquiry to us or Call us. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2023

Suppliers with verified business licenses

Import & Export Mode
Have Own Export License
Terms of Payment
LC, T/T, Western Union
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DDP, DAP