A water cooling system for electroplating is a specialized system designed to cool down the electroplating tank and maintain a stable temperature during the electroplating process. It typically consists of the following components:
Chiller: The chiller is the main component of the water cooling system. It circulates chilled water to remove heat from the electroplating tank. The chiller uses a refrigeration cycle to cool the water and maintain the desired temperature.
Heat Exchanger: A heat exchanger is used to transfer the heat from the water in the electroplating tank to the chilled water from the chiller. It helps maintain the proper temperature of the electroplating solution.
Circulation Pump: The circulation pump helps circulate the chilled water from the chiller through the heat exchanger and back to the electroplating tank. It ensures a continuous flow of cooled water to maintain consistent temperature control.
Temperature Controller: A temperature controller is used to monitor and control the temperature of the water in the electroplating tank. It helps maintain the desired temperature range for optimal electroplating results.
Piping and Valves: Piping and valves are used to connect the chiller, heat exchanger, and electroplating tank, allowing the flow of chilled water to and from the tank.
The water cooling system for electroplating is crucial for controlling the temperature of the electroplating solution. It helps prevent overheating or temperature fluctuations, ensuring the quality and consistency of the electroplated products. By removing excess heat generated during the electroplating process, it improves the efficiency of the plating operation and extends the life of the plating solution.
Main features of electroplating chillerAn anti-corrosion water chiller is typically used in environments where there is a need to cool corros liquids or fluids, as in chemical processing plants, laboratories, or industrial applications involving corrosive materials. The chiller is designed with specific materials and components that are resistant to corrosion, ensuring the reliability and longevity of the cooling system.
Some key applications of anti-corrosion water chillers include:
Chemical Processing: In industries where corrosive chemicals are involved, such as in the production of acids, alkalis, or other corrosive substances, an anti-corrosion water chiller is essential to maintain optimal temperatures and protect equipment from damage.
Pharmaceuticals and Biotechnology: Temperature control is crucial in pharmaceutical and biotech processes. Anti-corrosion water chillers are used to cool equipment like reactors, fermenters, and storage tanks, ensuring product quality and equipment longevity.
Metal Surface Treatment: Electroplating, anodizing, or other surface treatment processes require precise temperature control. Anti-corrosion chillers are capable of cooling the process baths and tanks, preventing damage to the substrates and maintaining consistent product quality.
Food and Beverage Processing: In certain applications where corrosive substances are used for cleaning or sanitation purposes, an anti-corrosion water chiller can be used to cool the wash-down equipment or provide chilled water for food and beverage processing.
These are just a few examples of the applications of anti-corrosion water chillers. The specific requirements of each application may vary, but the focus is always on maintaining the integrity and efficiency of the cooling system when dealing with corrosive substances or environments.
Model Item |
OMC-1A | OMC-2A | OMC-3A | OMC-5A | OMC-8A | OMC-10A | OMC-15A | OMC-20A | OMC-25A | OMC-30A | OMC-40A | ||
Cooling Capacity | KW | 2.7 | 5.4 | 8.1 | 13.5 | 21.6 | 27 | 40.5 | 54 | 67.5 | 81 | 108 | |
Kcal/h | 2322 | 4644 | 6966 | 11610 | 18576 | 23220 | 34830 | 46440 | 58050 | 69660 | 92880 | ||
Ton | 0.8 | 1.5 | 2.3 | 3.8 | 6.1 | 7.7 | 11.5 | 15.4 | 19.2 | 23.0 | 30.7 | ||
Btu/h | 9215 | 18430 | 27645 | 46075 | 73720 | 92150 | 138225 | 184300 | 230375 | 276451 | 368601 | ||
Input Power | KW | 1.4 | 2.1 | 2.8 | 5 | 7.3 | 9.2 | 14 | 18 | 22 | 28 | 36 | |
Power supply | 1PH-220V 50Hz | 3PH-380V 50Hz | |||||||||||
Temperature Range | ºC | 5-35 | |||||||||||
Refrigerant | Type | R22(R407C/R410A/R134A) | |||||||||||
Compressor | Control Mode | Capillary | Expansion Valve | ||||||||||
Type | Piston Type / Scroll Type | ||||||||||||
Power | KW | 0.75 | 1.5 | 2.2 | 4 | 6 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | |
Chilled water | Tank Volume | L | 25 | 30 | 60 | 65 | 150 | 180 | 300 | 400 | 400 | 540 | 630 |
Tank Material | SUS304 Stainless Steel | ||||||||||||
Pipe Diameter | inch | 1/2 | 3/4 | 3/4 | 1 | 1-1/2 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | |
Pump | Lift | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | |
Power | 0.37 | 0.37 | 0.37 | 0.75 | 1.1 | 1.5 | 1.5 | 2.2 | 2.2 | 4 | 4 | ||
Evaporator | Type | Tank with coil(Shell and Tube) | |||||||||||
Chilled Water Flow | m³/h | 0.5 | 0.9 | 1.4 | 2.3 | 3.7 | 4.6 | 7.0 | 9.3 | 11.6 | 13.9 | 18.6 | |
Condenser | Type | High efficiency copper condensing coil with Aluminum+Spiral axial flow fan | |||||||||||
Cooling Air Flow | m³/h | 1000 | 2000 | 3000 | 5000 | 8000 | 10000 | 15000 | 20000 | 25000 | 30000 | 40000 | |
Safety Protection | Compressor overheating protection, over-current protection, high and low pressure protection, over-temperature protection, flow protection, reversed and lacking phase protection, exhaust overheating protection. | ||||||||||||
Dimension | Length | mm | 680 | 770 | 1000 | 1120 | 1250 | 1500 | 2080 | 2100 | 2100 | 2300 | 2430 |
Width | mm | 420 | 500 | 480 | 530 | 680 | 770 | 780 | 850 | 850 | 930 | 1185 | |
Height | mm | 850 | 950 | 1100 | 1200 | 1350 | 1400 | 1650 | 1600 | 1700 | 1650 | 1710 | |
Weight | KG | 73 | 95 | 128 | 172 | 300 | 350 | 750 | 850 | 950 | 1080 | 1360 |
Air-cooled chiller is a common industrial cooling equipment with the following advantages:
Independent cooling system: The air-cooled chiller adopts an independent air cooling system and does not require additional cooling water sources or cooling towers. This makes installation and operation relatively simple, saving installation and maintenance costs and space.
Wide range of applications: Air-cooled chillers are suitable for various industrial applications, including plastic processing, refrigeration and air conditioning systems, machining, printing and paper making. They provide reliable cooling for different equipment and processes.
High efficiency and energy saving: The air-cooled chiller adopts air cooling method and uses forced fans to circulate the air and take away the heat. Compared to traditional water-cooled systems, they do not require additional water pumps and cooling towers, thus saving energy and operating costs.
Flexibility and mobility: Since they do not need to be connected to an external cooling water source, air-cooled chillers are more flexible and can be moved to different locations more easily. This is useful for applications that require movement or changes in work location.
Easy maintenance: Compared with water cooling systems, air-cooled chillers are easier to maintain. There is no need to deal with problems such as scale, water treatment and water pump maintenance, reducing the complexity and cost of maintenance work.
Small footprint: Air-cooled chillers have a relatively small footprint as they do not require a cooling tower and water cooling system. This is very advantageous when space is limited.
However, it should be noted that air-cooled chillers may be slightly less efficient than water-cooled systems in heat dissipation efficiency, especially in high-temperature environments. In addition, since air cooling requires the use of fans, noise and vibration may occur. Therefore, when selecting cooling equipment, it is necessary to comprehensively consider the advantages and disadvantages based on specific needs and process requirements, and weigh various factors.
Q1: Could you help us to recommend the model for our project?
A1: Yes, we have engineer to check the details and make the scheme for you. Based on the following:
1)Cooling capacity;
2)chilled water inlet and outlet temperature
3)chilled water flow
4) Refrigerant;
5) Ambient temperature;
6)Voltage;
7) Be used for what industry?
8)Any other special requirements
Q2: How to ensure your product with good quality?
A2: All our products with CE certificate. And use the well-know brand compressors and refrigeration accessories . All OUMAL Chillers are factory tested under load conditions to ensure good quality and easy installation for users.
Q3: What's the warranty?
A3: 15 months warranty for free if confirmed by both side damage in the quality reason.
Q4: What's your payment term?
A4: We accept T/T, LC, Western Union, etc. Normally, 30% deposit for production, 70% balance before shipment.
Q5: Are you a manufacturer?
A5: Yes, we have more than 15 years in water chiller business. Also have patent on the water chiller appearance .
The control box design make the unit safety and stably.