Customization: | Available |
---|---|
After-sales Service: | 7 X 24 Hours |
Warranty: | 15 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
An air-cooled chiller is a type of cooling system that uses the ambient air to dissipate heat and cool a process or a space. It is commonly used in commercial and industrial applications to provide chilled water for air conditioning, process cooling, and other cooling needs.
The basic principle of an air-cooled chiller involves the transfer of heat from the process or space to be cooled to the ambient air. Here's how it works:
Refrigeration Cycle: The air-cooled chiller uses a refrigeration cycle to remove heat. It comprises four main components: a compressor, a condenser, an expansion valve, and an evaporator. The refrigerant, typically a type of coolant like R-134a, circulates through these components to facilitate heat transfer.
Evaporator: The evaporator is where the heat exchange takes place. The warm water or coolant from the process is pumped into the evaporator. As the refrigerant flows through the evaporator, it absorbs the heat from the water or coolant, causing the water to cool down.
Compressor: After absorbing the heat, the refrigerant in a gaseous state is compressed by the compressor. The compression increases the pressure and temperature of the refrigerant, making it ready for the next stage.
Condenser: The high-pressure, high-temperature refrigerant then enters the condenser, where it releases the heat it had absorbed in the evaporator. The condenser is a heat exchanger with many fins or tubes that increase the cooling surface area. As the ambient air flows through the condenser, it absorbs the heat from the refrigerant, causing the refrigerant to condense back into a liquid state.
Expansion Valve: After condensing, the high-pressure liquid refrigerant passes through the expansion valve, which reduces its pressure and temperature. This process prepares the refrigerant for re-entering the evaporator and beginning the cycle again.
Air-cooling: In an air-cooled chiller, the condenser relies on a fan or fans to draw ambient air over the condenser coils and fins. As the air passes through the condenser, it absorbs the heat from the refrigerant, cooling it down and allowing it to condense.
Discharge: The cooled refrigerant then returns to the evaporator, and the cycle repeats to maintain the desired cooling effect.
Overall, the air-cooled chiller works by using the refrigeration cycle to transfer heat from the process to be cooled to the surrounding air, effectively cooling the process or space. It eliminates the need for an external cooling tower and associated water connections, making it a more compact and convenient cooling solution.
If you're looking for cooling equipment specifically for a PET bottle blowing machine, an industrial water cooling chiller would be a suitable choice. Water cooling chillers are commonly used in industrial applications to regulate the temperature of machinery and equipment.
An industrial chilling machine typically consists of a compressor, condenser, evaporator, and various control components. It works by circulating chilled water through the system to absorb heat generated by the equipment.
When choosing an industrial chilling machine for your PET bottle blowing machine, consider the following factors:
Cooling capacity: Ensure that the chiller has sufficient cooling capacity to meet the heat load requirements of your PET bottle blowing machine. The cooling capacity should be able to handle the maximum production capacity of the machine.
Temperature control: Look for a chiller with precise temperature control capabilities. PET bottle blowing machines often require specific temperature ranges for optimal production results.
Energy efficiency: Select a chiller that is energy-efficient to minimize operating costs. Look for features such as variable speed compressors and energy-saving modes.
Reliability: Choose a reliable chiller from a reputable manufacturer to ensure consistent performance and minimize downtime.
Maintenance and accessibility: Consider the ease of maintenance and accessibility to components. A chiller with easy-to-access components and serviceable parts will make maintenance tasks more convenient.
It is recommended to consult with a professional or the manufacturer of your PET bottle blowing machine to determine the specific cooling requirements and to select a suitable industrial water cooling chiller for your application.
The main features of industrial chilling equipment, such as a water cooling chiller plant, include:
Cooling Capacity: Industrial chillers are designed to provide high cooling capacity to meet the requirements of large-scale industrial processes. They are capable of cooling large volumes of water or other process fluids efficiently.
Precise Temperature Control: Industrial chillers have precise temperature control capabilities, allowing them to maintain a stable and accurate temperature range. This is crucial for industries that require precise temperature control in their manufacturing processes.
Energy Efficiency: Industrial chillers are designed to be energy-efficient, as they consume a significant amount of power. They incorporate advanced technologies like variable speed compressors, heat recovery systems, and energy-saving components to minimize energy consumption and reduce operating costs.
Reliability and Durability: Industrial chillers are built to withstand heavy-duty use and operate reliably even in demanding industrial environments. They are constructed with high-quality components, corrosion-resistant materials, and robust designs to ensure long-term performance and durability.
Low Maintenance: Industrial chillers are designed for easy maintenance and accessibility to components. They often have features like removable panels, easy-to-clean heat exchangers, and user-friendly controls, making maintenance tasks more convenient and minimizing downtime.
Safety Features: Industrial chillers incorporate various safety measures to protect the equipment and ensure the safety of operators and the surrounding environment. These may include high-temperature alarms, low-temperature alarms, pressure sensors, and fault detection systems.
Control and Monitoring: Industrial chillers are equipped with advanced control systems that provide comprehensive monitoring and control capabilities. These systems allow operators to adjust settings, monitor performance parameters, and diagnose any issues for efficient operations.
Customization Options: Industrial chillers can be customized to suit specific industry requirements. They can be tailored in terms of design, size, cooling capacity, and control options to meet the unique needs of each application.
Overall, industrial chilling equipment combines high cooling capacity, precise temperature control, energy efficiency, reliability, and easy maintenance to ensure optimal performance and productivity in industrial processes.
Specifications:
Model Item |
OMC-3W | OMC-5W | OMC-8W | OMC-10W | OMC-12W | OMC-15W | OMC-20W | OMC-25W | OMC-30W | OMC-40W | OMC-50W | ||
Cooling Capacity | KW | 9 | 15 | 24 | 30 | 36 | 45 | 60 | 75 | 90 | 120 | 150 | |
Kcal/h | 7740 | 12900 | 20640 | 25800 | 30960 | 38700 | 51600 | 64500 | 77400 | 103200 | 129000 | ||
Ton | 2.5 | 4.2 | 6.8 | 8.5 | 10.2 | 12.8 | 17.0 | 21.3 | 25.5 | 34.1 | 42.6 | ||
Btu/h | 30716 | 51194 | 81911 | 102389 | 122866 | 153583 | 204778 | 255973 | 307167 | 409556 | 511945 | ||
Input power | KW | 2.62 | 4.5 | 6.75 | 8.25 | 10.2 | 12.75 | 17.2 | 20.95 | 26.5 | 34 | 43 | |
Power supply | 3 PH-380V 50Hz | ||||||||||||
Temperature Range | ºC | 5-35 | |||||||||||
Refrigerant | Type | R22(R407C/R410A/R134A) | |||||||||||
Compressor | Control Mode | Capillary | Expansion Valve | ||||||||||
Type | Scroll type / Piston Type | ||||||||||||
Power | KW | 2.25 | 3.75 | 6 | 7.5 | 9 | 11.25 | 15 | 18.75 | 22.5 | 30 | 37.5 | |
Chilled water | Tank Volume | L | 60 | 70 | 150 | 180 | 240 | 300 | 400 | 400 | 540 | 630 | 700 |
Tank Material | SUS304 Stainless Steel | ||||||||||||
Pipe Diameter | 1-1/2" | 1-1/2" | 1-1/2" | 1-1/2" | 1-1/2" | 2" | 2" | 2-1/2" | 2-1/2" | 3" | 3" | ||
Pump | Lift | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | |
Power | 0.37 | 0.75 | 0.75 | 0.75 | 1.2 | 1.5 | 2.2 | 2.2 | 4 | 4 | 5.5 | ||
Evaporator | Type | Tank with coil(Shell and tube) | |||||||||||
Chilled water flow | m³/h | 1.5 | 2.6 | 4.1 | 5.2 | 6.2 | 7.7 | 10.3 | 12.9 | 15.5 | 20.6 | 25.8 | |
Condenser | Type | Shell and tube | |||||||||||
Cooling water flow | m³/h | 1.95 | 3.37 | 5.26 | 6.62 | 7.95 | 9.89 | 13.26 | 16.50 | 20.06 | 26.45 | 33.20 | |
Safety Protection | Compressor overheating protection, over-current protection, high and low pressure protection, over-temperature protection, flow protection,reversed and lacking phase protection, exhaust overheating protection. | ||||||||||||
Dimension | Length | mm | 850 | 900 | 1100 | 1250 | 1300 | 1450 | 1600 | 1620 | 1650 | 1900 | 2000 |
Width | mm | 500 | 500 | 680 | 600 | 600 | 780 | 850 | 850 | 850 | 1000 | 1000 | |
Height | mm | 880 | 980 | 1300 | 1300 | 1350 | 1350 | 1460 | 1480 | 1500 | 1650 | 1700 | |
Weight | KG | 130 | 160 | 300 | 450 | 680 | 740 | 820 | 900 | 1100 | 1300 | 1500 |
Water-cooled water chillers have a wide range of applications in various industries and processes where cooling is required. Some common applications include:
HVAC Systems: Water-cooled chillers are commonly used in building air conditioning systems to provide cooling for offices, commercial spaces, and residential complexes.
Industrial Processes: Water-cooled chillers are extensively used in industrial processes such as plastic injection molding, metalworking, chemical manufacturing, pharmaceutical production, food and beverage processing, and data centers. They help control the temperature of equipment and materials, ensuring efficient operation and product quality.
Power Generation: Water-cooled chillers are often employed in power plants to cool turbines, generators, and other equipment for efficient and reliable operation of the power generation process.
Refrigeration Systems: Water-cooled chillers are used in refrigeration systems for preserving perishable goods, such as in cold storage warehouses, food processing facilities, and supermarkets.
Medical and Laboratory Equipment: Water-cooled chillers are utilized to cool medical imaging machines, laboratory equipment, research instruments, and other precision equipment that require precise and stable temperature control.
Printing and Packaging: Water-cooled chillers play a vital role in maintaining the temperature of printing presses and packaging equipment, ensuring optimal performance and quality of printed materials.
Plastics and Rubber Industry: In manufacturing processes such as extrusion, blow molding, and thermoforming, water-cooled chillers are used to cool molds and maintain consistent temperature control during the production of plastic and rubber products.
Chemical and Petrochemical Industry: Water-cooled chillers are widely used in the chemical and petrochemical industry to cool reaction vessels, chemical reactors, and other equipment involved in chemical processes.
These are just a few examples of the many applications where water-cooled water chillers are employed. Their versatility, efficiency, and reliable cooling capabilities make them an essential component in various industries and processes.
Q1: Could you help us to recommend the model for our project?
A1: Yes, we have engineer to check the details and make the scheme for you. Based on the following:
1)Cooling capacity;
2)chilled water inlet and outlet temperature
3)chilled water flow
4) Refrigerant;
5) Ambient temperature;
6)Voltage;
7) Be used for what industry?
8)Any other special requirements
Q2: How to ensure your product with good quality?
A2: All our products with CE certificate. And use the well-know brand compressors and refrigeration accessories . All OUMAL Chillers are factory tested under load conditions to ensure good quality and easy installation for users.
Q3: What's the warranty?
A3: 15 months warranty for free if confirmed by both side damage in the quality reason.
Q4: What's your payment term?
A4: We accept T/T, LC, Western Union, etc. Normally, 30% deposit for production, 70% balance before shipment.
Q5: Are you a manufacturer?
A5: Yes, we have more than 15 years in water chiller business. Also have patent on the water chiller appearance .
The control box design make the unit safety and stably.
Q6: How can i Place an order
A6: Send inquiry to us or Call us.