Customization: | Available |
---|---|
After-sales Service: | 7 X 24 Hours |
Warranty: | 15 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Some main features of a water cooling chiller machine include:
High capacity: Water cooling chillers are designed to provide sufficient cooling capacity to meet the specific requirements of the process or equipment being cooled.
Precise temperature control: These chillers can maintain a stable and accurate temperature control, ensuring consistent cooling performance.
Energy efficiency: Water cooling chillers are designed to be energy-efficient, with advanced compressors and heat exchangers that optimize cooling performance while minimizing energy consumption.
Reliability: The chiller's components are built with high-quality materials and undergo rigorous testing to ensure long-term reliability and durability.
Easy maintenance: Water cooling chillers are designed for easy maintenance, with accessible components and user-friendly controls that simplify troubleshooting and servicing.
Safety features: Chiller units may include safety measures such as overload protection, high/low pressure alarms, and automatic shutdown in case of any abnormal conditions.
Compact design: Many water cooling chiller machines are designed to be compact, allowing for easy installation in various industrial settings where space may be limited.
It's important to note that specific features may vary depending on the manufacturer and model of the water cooling chiller machine.
The 15-ton air-cooled chiller is one of the best-selling industrial chillers, and we also call it the 20HP air-cooled chiller. A complete air-cooled chiller includes a compressor, condenser, fan, evaporator, circulating chilled water tank, and control system. The chilled water tank is generally installed inside the chiller chassis, with a volume of about 200Liters. If the customer has requirements for the capacity of the circulating water tank, we can make an external circulating water tank to meet the customer's needs. Of course, if the customer has his own water tank, the chiller does not need to be equipped with a water tank. Model Item |
OMC-1A | OMC-2A | OMC-3A | OMC-5A | OMC-8A | OMC-10A | OMC-15A | OMC-20A | OMC-25A | OMC-30A | OMC-40A | ||
Cooling Capacity | KW | 2.7 | 5.4 | 8.1 | 13.5 | 21.6 | 27 | 40.5 | 54 | 67.5 | 81 | 108 | |
Kcal/h | 2322 | 4644 | 6966 | 11610 | 18576 | 23220 | 34830 | 46440 | 58050 | 69660 | 92880 | ||
Ton | 0.8 | 1.5 | 2.3 | 3.8 | 6.1 | 7.7 | 11.5 | 15.4 | 19.2 | 23.0 | 30.7 | ||
Btu/h | 9215 | 18430 | 27645 | 46075 | 73720 | 92150 | 138225 | 184300 | 230375 | 276451 | 368601 | ||
Input Power | KW | 1.4 | 2.1 | 2.8 | 5 | 7.3 | 9.2 | 14 | 18 | 22 | 28 | 36 | |
Power supply | 1PH-220V 50Hz | 3PH-380V 50Hz | |||||||||||
Temperature Range | ºC | 5-35 | |||||||||||
Refrigerant | Type | R22(R407C/R410A/R134A) | |||||||||||
Compressor | Control Mode | Capillary | Expansion Valve | ||||||||||
Type | Piston Type / Scroll Type | ||||||||||||
Power | KW | 0.75 | 1.5 | 2.2 | 4 | 6 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | |
Chilled water | Tank Volume | L | 25 | 30 | 60 | 65 | 150 | 180 | 300 | 400 | 400 | 540 | 630 |
Tank Material | SUS304 Stainless Steel | ||||||||||||
Pipe Diameter | inch | 1/2 | 3/4 | 3/4 | 1 | 1-1/2 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | |
Pump | Lift | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | |
Power | 0.37 | 0.37 | 0.37 | 0.75 | 1.1 | 1.5 | 1.5 | 2.2 | 2.2 | 4 | 4 | ||
Evaporator | Type | Tank with coil(Shell and Tube) | |||||||||||
Chilled Water Flow | m³/h | 0.5 | 0.9 | 1.4 | 2.3 | 3.7 | 4.6 | 7.0 | 9.3 | 11.6 | 13.9 | 18.6 | |
Condenser | Type | High efficiency copper condensing coil with Aluminum+Spiral axial flow fan | |||||||||||
Cooling Air Flow | m³/h | 1000 | 2000 | 3000 | 5000 | 8000 | 10000 | 15000 | 20000 | 25000 | 30000 | 40000 | |
Safety Protection | Compressor overheating protection, over-current protection, high and low pressure protection, over-temperature protection, flow protection, reversed and lacking phase protection, exhaust overheating protection. | ||||||||||||
Dimension | Length | mm | 680 | 770 | 1000 | 1120 | 1250 | 1500 | 2080 | 2100 | 2100 | 2300 | 2430 |
Width | mm | 420 | 500 | 480 | 530 | 680 | 770 | 780 | 850 | 850 | 930 | 1185 | |
Height | mm | 850 | 950 | 1100 | 1200 | 1350 | 1400 | 1650 | 1600 | 1700 | 1650 | 1710 | |
Weight | KG | 73 | 95 | 128 | 172 | 300 | 350 | 750 | 850 | 950 | 1080 | 1360 |
Air-cooled chiller is a common industrial cooling equipment with the following advantages:
Independent cooling system: The air-cooled chiller adopts an independent air cooling system and does not require additional cooling water sources or cooling towers. This makes installation and operation relatively simple, saving installation and maintenance costs and space.
Wide range of applications: Air-cooled chillers are suitable for various industrial applications, including plastic processing, refrigeration and air conditioning systems, machining, printing and paper making. They provide reliable cooling for different equipment and processes.
High efficiency and energy saving: The air-cooled chiller adopts air cooling method and uses forced fans to circulate the air and take away the heat. Compared to traditional water-cooled systems, they do not require additional water pumps and cooling towers, thus saving energy and operating costs.
Flexibility and mobility: Since they do not need to be connected to an external cooling water source, air-cooled chillers are more flexible and can be moved to different locations more easily. This is useful for applications that require movement or changes in work location.
Easy maintenance: Compared with water cooling systems, air-cooled chillers are easier to maintain. There is no need to deal with problems such as scale, water treatment and water pump maintenance, reducing the complexity and cost of maintenance work.
Small footprint: Air-cooled chillers have a relatively small footprint as they do not require a cooling tower and water cooling system. This is very advantageous when space is limited.
However, it should be noted that air-cooled chillers may be slightly less efficient than water-cooled systems in heat dissipation efficiency, especially in high-temperature environments. In addition, since air cooling requires the use of fans, noise and vibration may occur. Therefore, when selecting cooling equipment, it is necessary to comprehensively consider the advantages and disadvantages based on specific needs and process requirements, and weigh various factors.
Q1: Could you help us to recommend the model for our project?
A1: Yes, we have engineer to check the details and make the scheme for you. Based on the following:
1)Cooling capacity;
2)chilled water inlet and outlet temperature
3)chilled water flow
4) Refrigerant;
5) Ambient temperature;
6)Voltage;
7) Be used for what industry?
8)Any other special requirements
Q2: How to ensure your product with good quality?
A2: All our products with CE certificate. And use the well-know brand compressors and refrigeration accessories . All OUMAL Chillers are factory tested under load conditions to ensure good quality and easy installation for users.
Q3: What's the warranty?
A3: 15 months warranty for free if confirmed by both side damage in the quality reason.
Q4: What's your payment term?
A4: We accept T/T, LC, Western Union, etc. Normally, 30% deposit for production, 70% balance before shipment.
Q5: Are you a manufacturer?
A5: Yes, we have more than 15 years in water chiller business. Also have patent on the water chiller appearance .
The control box design make the unit safety and stably.
Q6: How can i Place an order
A6: Send inquiry to us or Call us.