• 180HP -20c Low Temperature Chiller System Glycol Water Chiller Industrial Glycol Chiller System
  • 180HP -20c Low Temperature Chiller System Glycol Water Chiller Industrial Glycol Chiller System
  • 180HP -20c Low Temperature Chiller System Glycol Water Chiller Industrial Glycol Chiller System
  • 180HP -20c Low Temperature Chiller System Glycol Water Chiller Industrial Glycol Chiller System
  • 180HP -20c Low Temperature Chiller System Glycol Water Chiller Industrial Glycol Chiller System
  • 180HP -20c Low Temperature Chiller System Glycol Water Chiller Industrial Glycol Chiller System

180HP -20c Low Temperature Chiller System Glycol Water Chiller Industrial Glycol Chiller System

After-sales Service: 7X 24 Hours
Warranty: 15 Months
Type: Water-Cooled
Cooling Method: Screw
Unit Structure: Integral
Selected Voltage: 380V/50HZ
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (15)

Basic Info.

Model NO.
OMC-180WSL
Compressor Number
1
Noise Level
Low
Application Fields
Food Processing
Application Machine
Combination machine
Certification
ISO, CE
Condition
New
Cooling Capacity
100 Ton/350kw
Compressor
Semi-Hermetic
Controller
LCD Touch / Siemes PLC
Refrigerant
R22/R404A
Transport Package
Plywood
Specification
180HP
Trademark
OUMAL
Origin
China
HS Code
8418692090
Production Capacity
500

Product Description

180HP -20C low temperature chiller system glycol water chiller industrial glycol chiller system 

Glycol water chiller also called low temperature water chiller. A glycol water chiller system is a type of cooling system that uses a mixture of water and glycol as the cooling medium. Glycol, typically ethylene or propylene glycol, is added to the water to lower its freezing point and inhibit bacterial growth. This type of chiller system is commonly used in applications where low-temperature cooling is required, such as in food and beverage processing, chemical plants, and HVAC systems.

The glycol water chiller system consists of several key components, including a compressor, condenser, evaporator, expansion valve, and a circulation pump. The compressor compresses the refrigerant gas, raising its temperature and pressure. The high-pressure gas then flows into the condenser, where it releases heat and condenses into a high-pressure liquid.

The high-pressure liquid refrigerant then enters the expansion valve, which reduces its pressure and temperature. As it passes through the evaporator, it absorbs heat from the glycol-water mixture circulating through the system. This heat transfer process cools the glycol-water mixture, which can then be used for various cooling applications, such as process cooling or air conditioning.

The chilled glycol-water mixture is pumped back into the system by a circulation pump to repeat the cooling process. The chilled water can be circulated through a network of pipes, coils, or heat exchangers to cool the desired equipment or space.

Glycol water chiller systems offer the advantage of providing efficient and reliable cooling for applications that require low-temperature operation. The glycol additive provides freeze protection, allowing the system to operate in colder environments without the risk of freezing the water and damaging the system.
180HP -20c Low Temperature Chiller System Glycol Water Chiller Industrial Glycol Chiller System

The working principle of a low-temperature water-cooled screw chiller is as follows:

  1. Refrigeration Cycle: The chiller operates based on the vapor compression refrigeration cycle. It uses a refrigerant, typically R134a or R407c, which undergoes phase changes between a high-pressure gas and a low-pressure liquid to absorb heat from the process fluid.

  2. Compressor: The chiller contains a screw compressor, which is the heart of the system. The compressor compresses the refrigerant vapor, increasing its pressure and temperature.

  3. Condenser: The high-pressure, high-temperature refrigerant vapor then flows into the condenser. In the water-cooled system, the condenser is cooled by water that circulates through the condenser coils. As the refrigerant gives off heat, it condenses into a high-pressure liquid.

  4. Expansion Valve: The high-pressure liquid refrigerant passes through an expansion valve, where its pressure is reduced. This results in a drop in temperature and the refrigerant changes into a low-pressure, low-temperature mixture of liquid and vapor.

  5. Evaporator: The low-pressure refrigerant mixture enters the evaporator, which is in contact with the process fluid that needs to be cooled. Heat is transferred from the process fluid to the refrigerant, causing the refrigerant to evaporate. This absorbs heat from the process fluid and cools it down.

  6. Refrigerant Return: The refrigerant vapor is then drawn back into the compressor to start the cycle again. The process fluid, now cooled, continues its flow to the desired application or process.

Overall, the low-temperature water-cooled screw chiller uses the principles of refrigeration to remove heat from the process fluid and maintain the desired low temperature. The continuous circulation of the refrigerant allows for efficient cooling and temperature control.


180HP -20c Low Temperature Chiller System Glycol Water Chiller Industrial Glycol Chiller SystemThe main feature of a glycol water cooled chiller system includes:

  1. Efficient Cooling: The glycol water mix provides effective cooling for various industrial processes, ensuring stable and reliable temperature control.

  2. Anti-Freezing Protection: The addition of glycol prevents the water from freezing at low temperatures, making it suitable for applications in cold climates or where the cooling process requires lower temperatures.

  3. Corrosion Prevention: The glycol in the system helps to inhibit corrosion and protect the components of the chiller system, extending its lifespan and reducing maintenance requirements.

  4. Flexible Temperature Range: Glycol water cooled chiller systems can provide a wide range of temperature control, allowing for precise cooling requirements depending on the specific application.

  5. Versatility: These chiller systems are suitable for various industries and applications, including food and beverage processing, pharmaceuticals, chemical production, HVAC systems, and more.

  6. Energy-efficient Operation: Glycol water cooled chiller systems are designed for energy efficiency, with advanced compressors and heat exchange technology to optimize cooling performance and reduce energy consumption.

  7. Reliable and Durable: The chiller system is built with robust components and is designed for continuous and long-term operation, ensuring reliable and consistent cooling performance.

  8. Easy Maintenance: The chiller system is generally easy to maintain, with accessible components and controls for troubleshooting and routine service.

Overall, the glycol water cooled chiller system offers efficient and reliable cooling with anti-freezing protection and corrosion prevention, making it a suitable solution for various industrial applications that require precise temperature control.

Compressor features:

•New screw type compressor with 20%-30% higher in efficiency.

•Cooling capacity control available at four steps (100%-75%-50%-25%), three steps (100%-66%-33%) or no steps control system.

•High efficiency, low noise and vibration, easy to install.

•Environmental protection refrigerant R134a, R407c available.

Control operation system:

•SIEMENS PLC program control system, human-computer interface with big LED touch panel, running state displaying in multi-language, and self-diagnosis for easy operation and supervision.

•Extended industrial interface, convenient for being computer monitor via network.

Completely safety protection function:

•Multi-safety protection by high and low pressure, compressor overheating, overloading, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating and anti-freezing.

180HP -20c Low Temperature Chiller System Glycol Water Chiller Industrial Glycol Chiller SystemSpecification: 
    Item                                     Model OMC-40WSL OMC-50WSL OMC-60WSL OMC-70WSL OMC-80WSL OMC-100WSL OMC-120WSL OMC-140WSL OMC-160WSL OMC-180WSL
Norminal  cooling capacity Temp -10ºC 71.7 94.1 102.5 124.9 137.1 186.9 222.7 265.9 307.4 345.7
-20ºC 49.4 64.2 71 85.5 95.8 127.9 152.1 180.8 211.1 235.4
-30ºC 30.8  40.1  44.3  53.4  59.9  79.9  95.0  112.9  131.9  147.0 
Input Power KW 35.7 45.4 50.8 59.4 66.8 88 104.8 123.8 145.4 162.4
Power Supply 3PH-380V/415V 50HZ(220V/440V  60HZ))
Refrigerant Type R22 (R404A)
Control Mode Expansion Valve
Compressor Type Semi-Hermetic Screw
Power KW  35.7 45.4 50.8 59.4 66.8 88 104.8 123.8 145.4 162.4
Start-up Mode   Y-
Capacity Control % 0-25-50-75-100 (0-33-66-100)
Evaporator Type Temp Shell and Tube
Chilled Water Flow -10ºC m3/h 12.3  16.2  17.6  21.5  23.6  32.1  38.3  45.7  52.9  59.5 
-20ºC 8.5  11.0  12.2  14.7  16.5  22.0  26.2  31.1  36.3  40.5 
-30ºC 5.3  6.9  7.6  9.2  10.3  13.7  16.3  19.4  22.7  25.3 
Pipe Diameter Inch 3" 3" 3" 3" 4" 4" 4" 5" 5" 6"
Condenser Type Shell and Tube
Cooling water flow m3/h 18.4  23.9  26.3  31.6  35.0  47.1  56.1  66.8  77.6  87.1 
Pipe Diameter Inch 3" 3" 3" 3" 4" 4" 4" 5" 5" 6"
Safety Protection Compressor over temperature protection, over load protection, high and low pressure protection, anti-freezing protection, reversed and lacking phase protection, fusible blug, flow switch
Dimension Length mm 1960 2130 2450 2450 2750 2750 2750 2750 3460 3460
Width mm 855 855 985 985 1050 1050 1050 1050 1250 1350
Height mm 1540 1540 1600 1600 1600 1600 1730 1730 1730 1760
Net Weight kg 820 950 1120 1300 1560 1720 2030 2200 2410 2630
Running Weight kg 970 1060 1270 1480 1780 1960 2250 2430 2470 2920

The application of a low temperature water-cooled screw chiller is typically found in various industrial processes that require precise cooling at low temperatures. Some common applications include:

  1. Food and Beverage Industry: Low temperature water-cooled screw chillers are used for cooling in food processing and preservation applications such as cold storage, freezing, and beverage production.

  2. Chemical and Pharmaceutical Industry: These chillers are utilized for precise temperature control in chemical reactions, pharmaceutical manufacturing, and laboratory settings where low temperature cooling is required.

  3. Plastics and Rubber Industry: Low temperature water-cooled screw chillers are used in plastic injection molding, extrusion, and other processes that require cooling to maintain product quality and consistency.

  4. HVAC Systems: These chillers can be employed in commercial and industrial HVAC systems where low temperature cooling is necessary for air conditioning, climate control, and temperature-sensitive equipment cooling.

  5. Research and Testing Facilities: Low temperature water-cooled screw chillers find application in research laboratories, testing facilities, and universities where precise and stable low temperature cooling is required for scientific experiments and testing.

Overall, low temperature water-cooled screw chillers are essential in various industries and processes that demand reliable and efficient cooling at low temperatures, ensuring optimal process control and product quality.

180HP -20c Low Temperature Chiller System Glycol Water Chiller Industrial Glycol Chiller System

              WHY OUMAL CAN BE YOUR RELIABLE CHILLER FACTORY
                                                                           15+ Manufacturing Experience  
                                                   
over 15 years of water chiller manufacturing experience
                                                                                     24/7 online support
                                                         
We will be 24/7 online to support your business
                                                                                  Non-standard  Costomization
                                              Custom design & fabrication of industrial water chiller system
                                                                                    Export to 39+ countries
Build up long term cooperation more than 100 customers,70% supply to oversea market
  15 months warranty time
We provide 15 months warranty for all chillers
Lifetime service
We provide chiller whole lifetime service for you
180HP -20c Low Temperature Chiller System Glycol Water Chiller Industrial Glycol Chiller System
180HP -20c Low Temperature Chiller System Glycol Water Chiller Industrial Glycol Chiller System

FAQ

Q1: Could you help us to recommend the model for our project?

A1: Yes, we have engineer to check the details and make the scheme for you. Based on the following:

1)Cooling capacity;

2)chilled water inlet and outlet temperature

3)chilled water flow

4) Refrigerant;

5) Ambient temperature;

6)Voltage;

7) Be used for what industry?

8)Any other special requirements?

 

Q2: How to ensure your product with good quality?

A2: All our products with CE certificate. And use the well-know brand accessories. All OUMAL Chillers are factory tested under load conditions to ensure good quality and easy installation for users

 

Q3: What's the warranty?

A3: 15 months warranty for free if confirmed by both side damage in the quality reason.

 

Q4: Whats your payment term?

A4: We accept T/T, LC, Western Union, etc. Normally, 30% deposit for production, 70% balance before shipment.

 

Q5: Are you a manufacturer?

A5: Yes, we have more than 15 years in water chiller business. Also have patent on the water chiller appearance.The control box design make the unit safety and stably.

 

Q6: How can i Place an order

A6: Fill the table below to send an inquiry or Call us.



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2023

Suppliers with verified business licenses

Import & Export Mode
Have Own Export License
Terms of Payment
LC, T/T, Western Union
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DDP, DAP