Customization: | Available |
---|---|
After-sales Service: | 7 X 24 Hours |
Warranty: | 15 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
An industrial water chiller machine is specialized system used for cooling various industrial processes equipment. It works extracting heat from water and dissipating it through a refrigeration cycle. key features of an industrial water chiller include:
Cooling Capacity: It should have sufficient cooling capacity to meet the specific requirements of the industrial process or equipment it is intended to cool.
Temperature Control: Precise temperature control is crucial to maintain the desired cooling temperature consistently and accurately.
Energy Efficiency: High energy efficiency is important to minimize energy consumption and reduce operating costs.
Reliability: The chiller should be reliable and capable of continuous operation to ensure uninterrupted cooling for industrial processes.
Durability: Industrial water chillers should be built with robust and durable components to withstand the harsh and demanding conditions of industrial environments.
Easy Maintenance: The chiller system should be designed for easy maintenance and accessibility to components, allowing for convenient servicing and repairs.
Safety Features: It should have necessary safety features such as temperature and pressure alarms, overload protection, and fault diagnostics to ensure safe operation.
Control System: An effective control system with user-friendly interfaces enables easy monitoring and adjustment of the chiller's operation parameters.
Water Treatment Compatibility: If required, the chiller should be compatible with water treatment systems to prevent scaling, corrosion, and bacterial growth in the water circuit.
Compliance and Standards: The chiller should meet industry standards and regulations to ensure safe and efficient operation.
Industrial water chiller machines are widely used in various industries such as plastics processing, chemical manufacturing, food and beverage production, pharmaceuticals, printing, and many more, where precise and reliable cooling is essential for optimal productivity and product quality.
Industrial chiller is a type of chiller. Chillers can be divided into air-cooled chillers and water-cooled chillers. Model Item |
OMC-1A | OMC-2A | OMC-3A | OMC-5A | OMC-8A | OMC-10A | OMC-15A | OMC-20A | OMC-25A | OMC-30A | OMC-40A | ||
Cooling Capacity | KW | 2.7 | 5.4 | 8.1 | 13.5 | 21.6 | 27 | 40.5 | 54 | 67.5 | 81 | 108 | |
Kcal/h | 2322 | 4644 | 6966 | 11610 | 18576 | 23220 | 34830 | 46440 | 58050 | 69660 | 92880 | ||
Ton | 0.8 | 1.5 | 2.3 | 3.8 | 6.1 | 7.7 | 11.5 | 15.4 | 19.2 | 23.0 | 30.7 | ||
Btu/h | 9215 | 18430 | 27645 | 46075 | 73720 | 92150 | 138225 | 184300 | 230375 | 276451 | 368601 | ||
Input Power | KW | 1.4 | 2.1 | 2.8 | 5 | 7.3 | 9.2 | 14 | 18 | 22 | 28 | 36 | |
Power supply | 1PH-220V 50Hz | 3PH-380V 50Hz | |||||||||||
Temperature Range | ºC | 5-35 | |||||||||||
Refrigerant | Type | R22(R407C/R410A/R134A) | |||||||||||
Compressor | Control Mode | Capillary | Expansion Valve | ||||||||||
Type | Piston Type / Scroll Type | ||||||||||||
Power | KW | 0.75 | 1.5 | 2.2 | 4 | 6 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | |
Chilled water | Tank Volume | L | 25 | 30 | 60 | 65 | 150 | 180 | 300 | 400 | 400 | 540 | 630 |
Tank Material | SUS304 Stainless Steel | ||||||||||||
Pipe Diameter | inch | 1/2 | 3/4 | 3/4 | 1 | 1-1/2 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | |
Pump | Lift | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | |
Power | 0.37 | 0.37 | 0.37 | 0.75 | 1.1 | 1.5 | 1.5 | 2.2 | 2.2 | 4 | 4 | ||
Evaporator | Type | Tank with coil(Shell and Tube) | |||||||||||
Chilled Water Flow | m³/h | 0.5 | 0.9 | 1.4 | 2.3 | 3.7 | 4.6 | 7.0 | 9.3 | 11.6 | 13.9 | 18.6 | |
Condenser | Type | High efficiency copper condensing coil with Aluminum+Spiral axial flow fan | |||||||||||
Cooling Air Flow | m³/h | 1000 | 2000 | 3000 | 5000 | 8000 | 10000 | 15000 | 20000 | 25000 | 30000 | 40000 | |
Safety Protection | Compressor overheating protection, over-current protection, high and low pressure protection, over-temperature protection, flow protection, reversed and lacking phase protection, exhaust overheating protection. | ||||||||||||
Dimension | Length | mm | 680 | 770 | 1000 | 1120 | 1250 | 1500 | 2080 | 2100 | 2100 | 2300 | 2430 |
Width | mm | 420 | 500 | 480 | 530 | 680 | 770 | 780 | 850 | 850 | 930 | 1185 | |
Height | mm | 850 | 950 | 1100 | 1200 | 1350 | 1400 | 1650 | 1600 | 1700 | 1650 | 1710 | |
Weight | KG | 73 | 95 | 128 | 172 | 300 | 350 | 750 | 850 | 950 | 1080 | 1360 |
Air-cooled chiller is a common industrial cooling equipment with the following advantages:
Independent cooling system: The air-cooled chiller adopts an independent air cooling system and does not require additional cooling water sources or cooling towers. This makes installation and operation relatively simple, saving installation and maintenance costs and space.
Wide range of applications: Air-cooled chillers are suitable for various industrial applications, including plastic processing, refrigeration and air conditioning systems, machining, printing and paper making. They provide reliable cooling for different equipment and processes.
High efficiency and energy saving: The air-cooled chiller adopts air cooling method and uses forced fans to circulate the air and take away the heat. Compared to traditional water-cooled systems, they do not require additional water pumps and cooling towers, thus saving energy and operating costs.
Flexibility and mobility: Since they do not need to be connected to an external cooling water source, air-cooled chillers are more flexible and can be moved to different locations more easily. This is useful for applications that require movement or changes in work location.
Easy maintenance: Compared with water cooling systems, air-cooled chillers are easier to maintain. There is no need to deal with problems such as scale, water treatment and water pump maintenance, reducing the complexity and cost of maintenance work.
Small footprint: Air-cooled chillers have a relatively small footprint as they do not require a cooling tower and water cooling system. This is very advantageous when space is limited.
However, it should be noted that air-cooled chillers may be slightly less efficient than water-cooled systems in heat dissipation efficiency, especially in high-temperature environments. In addition, since air cooling requires the use of fans, noise and vibration may occur. Therefore, when selecting cooling equipment, it is necessary to comprehensively consider the advantages and disadvantages based on specific needs and process requirements, and weigh various factors.
Q1: Could you help us to recommend the model for our project?
A1: Yes, we have engineer to check the details and make the scheme for you. Based on the following:
1)Cooling capacity;
2)chilled water inlet and outlet temperature
3)chilled water flow
4) Refrigerant;
5) Ambient temperature;
6)Voltage;
7) Be used for what industry?
8)Any other special requirements
Q2: How to ensure your product with good quality?
A2: All our products with CE certificate. And use the well-know brand compressors and refrigeration accessories . All OUMAL Chillers are factory tested under load conditions to ensure good quality and easy installation for users.
Q3: What's the warranty?
A3: 15 months warranty for free if confirmed by both side damage in the quality reason.
Q4: What's your payment term?
A4: We accept T/T, LC, Western Union, etc. Normally, 30% deposit for production, 70% balance before shipment.
Q5: Are you a manufacturer?
A5: Yes, we have more than 15 years in water chiller business. Also have patent on the water chiller appearance .
The control box design make the unit safety and stably.
Q6: How can i Place an order
A6: Send inquiry to us or Call us.