Customization: | Available |
---|---|
After-sales Service: | 7X 24 Hours |
Warranty: | 15 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
-12C low temperature water cooled screw chiller for chemical industry 200KW industrial chiller
A -12°C low temperature water-cooled screw chiller is specifically designed for applications in the chemical industry that require a cooling capacity of 200 kW. This type of chiller is ideal for maintaining a stable and efficient cooling process in environments where precise temperature control is essential.
The chiller utilizes a water-cooled system, which means that it relies on a constant water supply to dissipate heat generated during the cooling process. This is achieved through the use of a water-cooled condenser, where the hot refrigerant gas is condensed into a liquid state by exchanging heat with the water flowing through the condenser pipes.
The chiller is equipped with a screw compressor, which is known for its efficiency and reliability in industrial applications. The screw compressor compresses the refrigerant gas, raising its temperature and pressure, and then sends it to the condenser for cooling.
To ensure efficient and reliable operation in the chemical industry, the chiller is designed with an anti-corrosion evaporator made of nickel white copper. This material is resistant to corrosion, making it suitable for handling the chemicals present in the cooling process.
The low temperature capability of -12°C makes this chiller suitable for a wide range of applications in the chemical industry, such as cooling processes involved in the production of chemicals, pharmaceuticals, or plastics. The precise temperature control provided by the chiller ensures that the desired temperature is maintained consistently, resulting in high-quality products and improved process efficiency.
Overall, the -12°C low temperature water-cooled screw chiller with an anti-corrosion evaporator is an excellent choice for industries requiring reliable and efficient cooling solutions in challenging chemical environments.
The working principle of a low-temperature water-cooled screw chiller is as follows:
Refrigeration Cycle: The chiller operates based on the vapor compression refrigeration cycle. It uses a refrigerant, typically R404A or R22, which undergoes phase changes between a high-pressure gas and a low-pressure liquid to absorb heat from the process fluid.
Compressor: The chiller contains a screw compressor, which is the heart of the system. The compressor compresses the refrigerant vapor, increasing its pressure and temperature.
Condenser: The high-pressure, high-temperature refrigerant vapor then flows into the condenser. In the water-cooled system, the condenser is cooled by water that circulates through the condenser coils. As the refrigerant gives off heat, it condenses into a high-pressure liquid.
Expansion Valve: The high-pressure liquid refrigerant passes through an expansion valve, where its pressure is reduced. This results in a drop in temperature and the refrigerant changes into a low-pressure, low-temperature mixture of liquid and vapor.
Evaporator: The low-pressure refrigerant mixture enters the evaporator, which is in contact with the process fluid that needs to be cooled. Heat is transferred from the process fluid to the refrigerant, causing the refrigerant to evaporate. This absorbs heat from the process fluid and cools it down.
Refrigerant Return: The refrigerant vapor is then drawn back into the compressor to start the cycle again. The process fluid, now cooled, continues its flow to the desired application or process.
Overall, the low-temperature water-cooled screw chiller uses the principles of refrigeration to remove heat from the process fluid and maintain the desired low temperature. The continuous circulation of the refrigerant allows for efficient cooling and temperature control.
The main feature of a glycol water cooled chiller system includes:
Efficient Cooling: The glycol water mix provides effective cooling for various industrial processes, ensuring stable and reliable temperature control.
Anti-Freezing Protection: The addition of glycol prevents the water from freezing at low temperatures, making it suitable for applications in cold climates or where the cooling process requires lower temperatures.
Corrosion Prevention: The glycol in the system helps to inhibit corrosion and protect the components of the chiller system, extending its lifespan and reducing maintenance requirements.
Flexible Temperature Range: Glycol water cooled chiller systems can provide a wide range of temperature control, allowing for precise cooling requirements depending on the specific application.
Versatility: These chiller systems are suitable for various industries and applications, including food and beverage processing, pharmaceuticals, chemical production, HVAC systems, and more.
Energy-efficient Operation: Glycol water cooled chiller systems are designed for energy efficiency, with advanced compressors and heat exchange technology to optimize cooling performance and reduce energy consumption.
Reliable and Durable: The chiller system is built with robust components and is designed for continuous and long-term operation, ensuring reliable and consistent cooling performance.
Easy Maintenance: The chiller system is generally easy to maintain, with accessible components and controls for troubleshooting and routine service.
Overall, the glycol water cooled chiller system offers efficient and reliable cooling with anti-freezing protection and corrosion prevention, making it a suitable solution for various industrial applications that require precise temperature control.
Compressor features:
•New screw type compressor with 20%-30% higher in efficiency.
•Cooling capacity control available at four steps (100%-75%-50%-25%), three steps (100%-66%-33%) or no steps control system.
•High efficiency, low noise and vibration, easy to install.
•Environmental protection refrigerant R134a, R407c available.
Control operation system:
•SIEMENS PLC program control system, human-computer interface with big LED touch panel, running state displaying in multi-language, and self-diagnosis for easy operation and supervision.
•Extended industrial interface, convenient for being computer monitor via network.
Completely safety protection function:
•Multi-safety protection by high and low pressure, compressor overheating, overloading, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating and anti-freezing.
Specification:Item Model | OMC-40WSL | OMC-50WSL | OMC-60WSL | OMC-70WSL | OMC-80WSL | OMC-100WSL | OMC-120WSL | OMC-140WSL | OMC-160WSL | OMC-180WSL | |||
Norminal cooling capacity | Temp | -10ºC | 71.7 | 94.1 | 102.5 | 124.9 | 137.1 | 186.9 | 222.7 | 265.9 | 307.4 | 345.7 | |
-20ºC | 49.4 | 64.2 | 71 | 85.5 | 95.8 | 127.9 | 152.1 | 180.8 | 211.1 | 235.4 | |||
-30ºC | 30.8 | 40.1 | 44.3 | 53.4 | 59.9 | 79.9 | 95.0 | 112.9 | 131.9 | 147.0 | |||
Input Power | KW | 35.7 | 45.4 | 50.8 | 59.4 | 66.8 | 88 | 104.8 | 123.8 | 145.4 | 162.4 | ||
Power Supply | 3PH-380V/415V 50HZ(220V/440V 60HZ)) | ||||||||||||
Refrigerant | Type | R22 (R404A) | |||||||||||
Control Mode | Expansion Valve | ||||||||||||
Compressor | Type | Semi-Hermetic Screw | |||||||||||
Power | KW | 35.7 | 45.4 | 50.8 | 59.4 | 66.8 | 88 | 104.8 | 123.8 | 145.4 | 162.4 | ||
Start-up Mode | Y-△ | ||||||||||||
Capacity Control | % | 0-25-50-75-100 (0-33-66-100) | |||||||||||
Evaporator | Type | Temp | Shell and Tube | ||||||||||
Chilled Water Flow | -10ºC | m3/h | 12.3 | 16.2 | 17.6 | 21.5 | 23.6 | 32.1 | 38.3 | 45.7 | 52.9 | 59.5 | |
-20ºC | 8.5 | 11.0 | 12.2 | 14.7 | 16.5 | 22.0 | 26.2 | 31.1 | 36.3 | 40.5 | |||
-30ºC | 5.3 | 6.9 | 7.6 | 9.2 | 10.3 | 13.7 | 16.3 | 19.4 | 22.7 | 25.3 | |||
Pipe Diameter | Inch | 3" | 3" | 3" | 3" | 4" | 4" | 4" | 5" | 5" | 6" | ||
Condenser | Type | Shell and Tube | |||||||||||
Cooling water flow | m3/h | 18.4 | 23.9 | 26.3 | 31.6 | 35.0 | 47.1 | 56.1 | 66.8 | 77.6 | 87.1 | ||
Pipe Diameter | Inch | 3" | 3" | 3" | 3" | 4" | 4" | 4" | 5" | 5" | 6" | ||
Safety Protection | Compressor over temperature protection, over load protection, high and low pressure protection, anti-freezing protection, reversed and lacking phase protection, fusible blug, flow switch | ||||||||||||
Dimension | Length | mm | 1960 | 2130 | 2450 | 2450 | 2750 | 2750 | 2750 | 2750 | 3460 | 3460 | |
Width | mm | 855 | 855 | 985 | 985 | 1050 | 1050 | 1050 | 1050 | 1250 | 1350 | ||
Height | mm | 1540 | 1540 | 1600 | 1600 | 1600 | 1600 | 1730 | 1730 | 1730 | 1760 | ||
Net Weight | kg | 820 | 950 | 1120 | 1300 | 1560 | 1720 | 2030 | 2200 | 2410 | 2630 | ||
Running Weight | kg | 970 | 1060 | 1270 | 1480 | 1780 | 1960 | 2250 | 2430 | 2470 | 2920 |
The application of a low temperature water-cooled screw chiller is typically found in various industrial processes that require precise cooling at low temperatures. Some common applications include:
Food and Beverage Industry: Low temperature water-cooled screw chillers are used for cooling in food processing and preservation applications such as cold storage, freezing, and beverage production.
Chemical and Pharmaceutical Industry: These chillers are utilized for precise temperature control in chemical reactions, pharmaceutical manufacturing, and laboratory settings where low temperature cooling is required.
Plastics and Rubber Industry: Low temperature water-cooled screw chillers are used in plastic injection molding, extrusion, and other processes that require cooling to maintain product quality and consistency.
HVAC Systems: These chillers can be employed in commercial and industrial HVAC systems where low temperature cooling is necessary for air conditioning, climate control, and temperature-sensitive equipment cooling.
Research and Testing Facilities: Low temperature water-cooled screw chillers find application in research laboratories, testing facilities, and universities where precise and stable low temperature cooling is required for scientific experiments and testing.
Overall, low temperature water-cooled screw chillers are essential in various industries and processes that demand reliable and efficient cooling at low temperatures, ensuring optimal process control and product quality.
WHY OUMAL CAN BE YOUR RELIABLE CHILLER FACTORYFAQ
Q1: Could you help us to recommend the model for our project?
A1: Yes, we have engineer to check the details and make the scheme for you. Based on the following:
1)Cooling capacity;
2)chilled water inlet and outlet temperature
3)chilled water flow
4) Refrigerant;
5) Ambient temperature;
6)Voltage;
7) Be used for what industry?
8)Any other special requirements?
Q2: How to ensure your product with good quality?
A2: All our products with CE certificate. And use the well-know brand accessories. All OUMAL Chillers are factory tested under load conditions to ensure good quality and easy installation for users
Q3: What's the warranty?
A3: 15 months warranty for free if confirmed by both side damage in the quality reason.
Q4: Whats your payment term?
A4: We accept T/T, LC, Western Union, etc. Normally, 30% deposit for production, 70% balance before shipment.
Q5: Are you a manufacturer?
A5: Yes, we have more than 15 years in water chiller business. Also have patent on the water chiller appearance.The control box design make the unit safety and stably.
Q6: How can i Place an order
A6: Fill the table below to send an inquiry or Call us.