In industrial settings, chilling machines are commonly used for cooling various processes and equipment. The cooling system typically consists: chillers, cooling towers, ice machines and Heat exchangers. The industrial chillers are the most widely used in the industrial cooling water systems. The cooling efficient of the chillers are better than the cooling towers. 10HP air to water cooled chiller is one of the hot saling industrial chillers.
Industrial cooling systems, often referred to as chillers, are essential for maintaining stable temperatures in various industrial processes. These systems use refrigeration technology to remove heat from process equipment or industrial environments, ensuring optimal performance and preventing equipment damage due to overheating. Here are some key features of industrial cooling systems or chillers:
Cooling Capacity: Industrial chillers are designed to provide sufficient cooling capacity to meet the specific requirements of the application. The cooling capacity is measured in tons, BTU/h (British Thermal Units per hour), or kilowatts (kW).
Temperature Control: Precise temperature control is crucial in industrial applications. Chillers should be able to maintain a stable and accurate temperature range to ensure the reliability and effectiveness of the cooling process.
Energy Efficiency: Energy efficiency is a significant consideration for industrial cooling systems, as they typically consume a significant amount of electricity. High-efficiency chillers help reduce energy consumption and operating costs while minimizing environmental impact.
Reliability and Durability: Industrial environments can be demanding, so chillers should be designed to withstand harsh conditions and prolonged operation. They should be built with robust components and have a reliable performance track record to ensure long-term reliability and minimal downtime.
Maintenance and Serviceability: Chillers should be easy to maintain and service. Accessible components and a well-designed layout facilitate routine maintenance, troubleshooting, and repairs, minimizing downtime and improving overall system efficiency.
Control and Monitoring: Advanced chilling systems incorporate intelligent control and monitoring features. These may include digital control panels, remote monitoring capabilities, alarms for system faults or temperature deviations, and integration with building management systems.
Safety Features: Industrial cooling systems should incorporate safety features to protect against potential hazards, such as high/low-pressure switches, refrigerant leak detection, and automatic shutdown mechanisms.
Compatibility and Flexibility: Chillers should be compatible with a wide range of industrial applications and adaptable to different process requirements. They should offer options for various cooling mediums (water, glycol, etc.) and be capable of handling different flow rates and pressure requirements.
Noise Reduction: Industrial chillers can produce significant noise levels, which can be disruptive in certain environments. Noise reduction features, such as vibration isolation, insulated enclosures, and low-noise fans, help minimize the impact on the surrounding environment and personnel.
Regulatory Compliance: Industrial cooling systems need to comply with relevant regulations and standards, such as safety standards, environmental regulations, and refrigerant regulations (e.g., compliance with the Montreal Protocol and phasing out of ozone-depleting substances).
These features contribute to the efficient and effective operation of industrial cooling systems, ensuring optimal performance, equipment longevity, and operational cost savings.
The main parts of a package-type Air-cooled water chiller typically include:
Compressor: The compressor is responsible for compressing the refrigerant vapor, raising its temperature and pressure.
The explosion proof water cooled chiller use explosion proof compressors. And the electric box is explosion proof. High quality.
Condenser: The condenser is a heat exchanger where the high-pressure, high-temperature refrigerant vapor releases heat and condenses into a liquid state when it comes into contact with the cool water circulating through the condenser.
Evaporator: The evaporator is another heat exchanger where the liquid refrigerant absorbs heat from the water or air being cooled. As the refrigerant absorbs this heat, it evaporates into a vapor state.
Expansion Valve: The expansion valve regulates the flow of refrigerant from the high-pressure side to the low-pressure side of the system, creating a pressure drop and allowing the refrigerant to evaporate and absorb heat efficiently in the evaporator.
Water Circulation System: The water circulation system includes pumps, pipes, and a water reservoir or cooling tower (if required) to constantly circulate the chilled water through the chiller's condenser and evaporator, facilitating the heat exchange process.
Control Panel: The control panel houses the electrical controls, sensors, and display interface for monitoring and controlling the chiller's operation. It allows users to set and adjust temperature parameters, monitor system performance, and ensure safe and efficient operation.
These components work together to extract heat from the water or air being cooled and transfer it to the surrounding environment through the water-cooled condenser. This process helps maintain the desired temperature of the chilled water or cooling medium in various industrial applications.
Specifications:
Model Item |
OMC-1A | OMC-2A | OMC-3A | OMC-5A | OMC-8A | OMC-10A | OMC-15A | OMC-20A | OMC-25A | OMC-30A | OMC-40A | ||
Cooling Capacity | KW | 2.7 | 5.4 | 8.1 | 13.5 | 21.6 | 27 | 40.5 | 54 | 67.5 | 81 | 108 | |
Kcal/h | 2322 | 4644 | 6966 | 11610 | 18576 | 23220 | 34830 | 46440 | 58050 | 69660 | 92880 | ||
Ton | 0.8 | 1.5 | 2.3 | 3.8 | 6.1 | 7.7 | 11.5 | 15.4 | 19.2 | 23.0 | 30.7 | ||
Btu/h | 9215 | 18430 | 27645 | 46075 | 73720 | 92150 | 138225 | 184300 | 230375 | 276451 | 368601 | ||
Input Power | KW | 1.4 | 2.1 | 2.8 | 5 | 7.3 | 9.2 | 14 | 18 | 22 | 28 | 36 | |
Power supply | 1PH-220V 50Hz | 3PH-380V 50Hz | |||||||||||
Temperature Range | ºC | 5-35 | |||||||||||
Refrigerant | Type | R22(R407C/R410A/R134A) | |||||||||||
Compressor | Control Mode | Capillary | Expansion Valve | ||||||||||
Type | Piston Type / Scroll Type | ||||||||||||
Power | KW | 0.75 | 1.5 | 2.2 | 4 | 6 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | |
Chilled water | Tank Volume | L | 25 | 30 | 60 | 65 | 150 | 180 | 300 | 400 | 400 | 540 | 630 |
Tank Material | SUS304 Stainless Steel | ||||||||||||
Pipe Diameter | 1/2 | 3/4 | 3/4 | 1 | 1-1/2 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | ||
Pump | Lift | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | |
Power | 0.37 | 0.37 | 0.37 | 0.75 | 1.1 | 1.5 | 1.5 | 2.2 | 2.2 | 4 | 4 | ||
Evaporator | Type | Tank with coil(Shell and Tube) | |||||||||||
Chilled Water Flow | m³/h | 0.5 | 0.9 | 1.4 | 2.3 | 3.7 | 4.6 | 7.0 | 9.3 | 11.6 | 13.9 | 18.6 | |
Condenser | Type | High efficiency copper condensing coil with Aluminum+Spiral axial flow fan | |||||||||||
Cooling Air Flow | m³/h | 1000 | 2000 | 3000 | 5000 | 8000 | 10000 | 15000 | 20000 | 25000 | 30000 | 40000 | |
Safety Protection | Compressor overheating protection, over-current protection, high and low pressure protection, over-temperature protection, flow protection, reversed and lacking phase protection, exhaust overheating protection. | ||||||||||||
Dimension | Length | mm | 680 | 770 | 1000 | 1120 | 1250 | 1500 | 2080 | 2100 | 2100 | 2300 | 2430 |
Width | mm | 420 | 500 | 480 | 530 | 680 | 770 | 780 | 850 | 850 | 930 | 1185 | |
Height | mm | 850 | 950 | 1100 | 1200 | 1350 | 1400 | 1650 | 1600 | 1700 | 1650 | 1710 | |
Weight | KG | 73 | 95 | 128 | 172 | 300 | 350 | 750 | 850 | 950 | 1080 | 1360 |
Water-cooled water chillers have a wide range of applications in various industries and processes where cooling is required. Some common applications include:
HVAC Systems: Water-cooled chillers are commonly used in building air conditioning systems to provide cooling for offices, commercial spaces, and residential complexes.
Industrial Processes: Water-cooled chillers are extensively used in industrial processes such as plastic injection molding, metalworking, chemical manufacturing, pharmaceutical production, food and beverage processing, and data centers. They help control the temperature of equipment and materials, ensuring efficient operation and product quality.
Power Generation: Water-cooled chillers are often employed in power plants to cool turbines, generators, and other equipment for efficient and reliable operation of the power generation process.
Refrigeration Systems: Water-cooled chillers are used in refrigeration systems for preserving perishable goods, such as in cold storage warehouses, food processing facilities, and supermarkets.
Medical and Laboratory Equipment: Water-cooled chillers are utilized to cool medical imaging machines, laboratory equipment, research instruments, and other precision equipment that require precise and stable temperature control.
Printing and Packaging: Water-cooled chillers play a vital role in maintaining the temperature of printing presses and packaging equipment, ensuring optimal performance and quality of printed materials.
Plastics and Rubber Industry: In manufacturing processes such as extrusion, blow molding, and thermoforming, water-cooled chillers are used to cool molds and maintain consistent temperature control during the production of plastic and rubber products.
Chemical and Petrochemical Industry: Water-cooled chillers are widely used in the chemical and petrochemical industry to cool reaction vessels, chemical reactors, and other equipment involved in chemical processes.
These are just a few examples of the many applications where water-cooled water chillers are employed. Their versatility, efficiency, and reliable cooling capabilities make them an essential component in various industries and processes.
Q1: Could you help us to recommend the model for our project?
A1: Yes, we have engineer to check the details and make the scheme for you. Based on the following:
1)Cooling capacity;
2)chilled water inlet and outlet temperature
3)chilled water flow
4) Refrigerant;
5) Ambient temperature;
6)Voltage;
7) Be used for what industry?
8)Any other special requirements
Q2: How to ensure your product with good quality?
A2: All our products with CE certificate. And use the well-know brand compressors and refrigeration accessories . All OUMAL Chillers are factory tested under load conditions to ensure good quality and easy installation for users.
Q3: What's the warranty?
A3: 15 months warranty for free if confirmed by both side damage in the quality reason.
Q4: What's your payment term?
A4: We accept T/T, LC, Western Union, etc. Normally, 30% deposit for production, 70% balance before shipment.
Q5: Are you a manufacturer?
A5: Yes, we have more than 15 years in water chiller business. Also have patent on the water chiller appearance .
The control box design make the unit safety and stably.
Q6: How can i Place an order
A6: Send inquiry to us or Call us.