Customization: | Available |
---|---|
After-sales Service: | 7 X 24 Hours |
Warranty: | 15 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
A 5HP custom piston air ch refers to an air-cooled chiller system that utilizes a semi-hermetic piston compressor for cooling applications. This specific chiller is designed to provide low-temperature glycol chilling, meaning it is capable of achieving and maintaining lower temperatures to meet the cooling requirements of the process or application.
The semi-hermetic piston compressor is an integral part of the chiller system that compresses the refrigerant to generate cooling. It is known for its reliable performance and robust construction, making it suitable for industrial applications that require a consistent cooling capacity.
The low-temperature glycol chiller configuration indicates that the chiller is capable of cooling glycol-based fluids to achieve the desired temperature range for the specific application. This type of chiller is commonly used in various industrial processes such as food processing, pharmaceuticals, chemical manufacturing, and more.
Overall, a 5HP custom piston air chiller with a semi-hermetic piston compressor provides a reliable and efficient solution for low-temperature glycol chilling applications in industrial settings.
An air-cooled glycol chiller is a type of chiller system that uses ambient air to cool the glycol refrigerant. It is specifically designed to cool processes that require a lower temperature, such as in the food and beverage industry, chemical processing, and HVAC applications.
The advantages of an air-cooled glycol chiller include:
No need for water source: Unlike water-cooled chillers that require a constant water supply, air-cooled glycol chillers can operate independently without the need for a water source. This makes them more adaptable in areas where water availability or quality is limited.
Energy efficiency: Air-cooled chillers eliminate the need for a cooling tower and associated water pumps, resulting in lower energy consumption. They have a higher coefficient of performance (COP) compared to water-cooled chillers, as there are no energy losses associated with pumping and maintaining water flow.
Lower installation and maintenance costs: Air-cooled glycol chillers are generally easier and less expensive to install since they do not require complex water piping systems. They also require less maintenance since there are no water-side heat exchangers to clean or treat for corrosion.
Flexibility in installation location: Air-cooled chillers can be installed indoors or outdoors, as they do not require access to a water source or make-up water supply. This provides more flexibility in terms of installation options and space utilization.
Reduced environmental impact: Air-cooled chillers do not consume large amounts of water for cooling, making them more environmentally friendly compared to water-cooled systems. They do not contribute to water waste or the potential for water contamination.
Overall, an air-cooled glycol chiller offers cost-effective and efficient cooling solutions for various industrial applications, providing flexibility, ease of installation, and environmental benefits.
Air-cooled scroll water chillers offer several advantages, including ease of installation, lower initial cost compared to water-cooled systems, and independence from water sources. However, their cooling capacity may be limited by ambient air temperature, and they tend to be less efficient in terms of energy consumption compared to water-cooled chillers.
Industrial chiller is a type of chiller. Chillers can be divided into air-cooled chillers and water-cooled chillers. Model Item |
Temp | OMC-3AL | OMC-5AL | OMC-6AL | OMC-8AL | OMC-10AL | OMC-12AL | OMC-15AL | OMC-20AL | OMC-25AL | OMC-30AL | OMC-40AL | ||
Cooling Capacity | KW | '-10ºC | 3.80 | 6.30 | 7.50 | 9.10 | 13.20 | 16.10 | 19.50 | 26.40 | 32.20 | 39.00 | 52.00 | |
'-20ºC | 1.90 | 3.00 | 4.00 | 6.00 | 7.10 | 8.00 | 13.90 | 16.90 | 20.80 | 24.40 | 30.80 | |||
'-30ºC | 1.00 | 1.60 | 1.90 | 2.70 | 3.20 | 3.80 | 6.10 | 9.50 | 12.10 | 14.30 | 19.00 | |||
'-35ºC | 0.67 | 1.04 | 1.50 | 2.30 | 2.80 | 3.00 | 4.30 | 6.35 | 8.30 | 10.10 | 13.35 | |||
Evaporator | Chilled water flow | '-10ºC | 0.65 | 1.10 | 1.30 | 1.60 | 2.30 | 2.80 | 3.40 | 4.50 | 5.60 | 6.70 | 9.00 | |
'-20ºC | 0.33 | 0.52 | 0.69 | 1.10 | 1.23 | 1.38 | 2.39 | 2.85 | 3.57 | 4.20 | 5.30 | |||
'-30ºC | 0.17 | 0.28 | 0.33 | 0.47 | 0.55 | 0.65 | 1.10 | 1.60 | 2.10 | 2.46 | 3.30 | |||
'-35ºC | 0.12 | 0.18 | 0.26 | 0.40 | 0.48 | 0.52 | 0.72 | 1.1 | 1.43 | 1.74 | 2.3 | |||
Type | Shell and tube / plate heat exchanger / tank with coil | |||||||||||||
Inlet/outlet pipe | Inch | 1" | 1" | 1" | 1" | 1-1/2" | 1-1/2" | 2" | 2" | 2" | 2-1/2" | 2-1/2" | ||
Input Power | kw | 3.18 | 4.86 | 5.61 | 7.25 | 9.4 | 10.9 | 13.5 | 18.8 | 22.55 | 28.5 | 37.5 | ||
Max Current | A | 7.8 | 12 | 13.7 | 18 | 23 | 26.5 | 33 | 46 | 55 | 69 | 91 | ||
Power supply | 3ph-380V/415V/440V/460V 50Hz/60hz | |||||||||||||
Refrigerant | Type | R22/R404A | ||||||||||||
Control | Thermostatic Expansion Valve | |||||||||||||
Compressor | Type | Hermetic Scroll / Semi-hermetic Piston | 540 | 630 | ||||||||||
Power | kw | 2.25 | 3.75 | 4.5 | 6 | 7.5 | 9 | 11.3 | 7.5 x 2 | 9.37 x 2 | 11.3 x 2 | 30 | ||
Condenser | Type | High Efficient finned copper tube with aluminum + Low noise external rotor fan | ||||||||||||
Water Pump | Power | kw | 0.75 | 0.75 | 0.75 | 0.75 | 1.1 | 1.1 | 1.1 | 1.5 | 2.2 | 2.2 | 4 | |
Lift | m | 0.7 | 1.1 | 1.6 | 2.3 | 3.4 | 4.5 | 5.5 | 6.7 | 8.9 | ||||
Safety Protection | Compressor inner protection, over current protection, high/low pressure protection, over temperature protection,flow rate protection, phase missing protection, low level coolant protection, anti freezing protection | |||||||||||||
Demension | Length | mm | 1000 | 1120 | 1120 | 1250 | 1500 | 1600 | 2080 | 2100 | 2100 | 2300 | 2430 | |
Width | mm | 480 | 530 | 600 | 680 | 770 | 770 | 780 | 850 | 850 | 930 | 1185 | ||
Height | mm | 1100 | 1200 | 1200 | 1350 | 1400 | 1500 | 1650 | 1600 | 1700 | 1650 | 1710 | ||
Net Weight | KG | KG | 128 | 172 | 185 | 300 | 350 | 500 | 750 | 850 | 950 | 1080 | 1360 |
Air-cooled chiller is a common industrial cooling equipment with the following advantages:
Independent cooling system: The air-cooled chiller adopts an independent air cooling system and does not require additional cooling water sources or cooling towers. This makes installation and operation relatively simple, saving installation and maintenance costs and space.
Wide range of applications: Air-cooled chillers are suitable for various industrial applications, including plastic processing, refrigeration and air conditioning systems, machining, printing and paper making. They provide reliable cooling for different equipment and processes.
High efficiency and energy saving: The air-cooled chiller adopts air cooling method and uses forced fans to circulate the air and take away the heat. Compared to traditional water-cooled systems, they do not require additional water pumps and cooling towers, thus saving energy and operating costs.
Flexibility and mobility: Since they do not need to be connected to an external cooling water source, air-cooled chillers are more flexible and can be moved to different locations more easily. This is useful for applications that require movement or changes in work location.
Easy maintenance: Compared with water cooling systems, air-cooled chillers are easier to maintain. There is no need to deal with problems such as scale, water treatment and water pump maintenance, reducing the complexity and cost of maintenance work.
Small footprint: Air-cooled chillers have a relatively small footprint as they do not require a cooling tower and water cooling system. This is very advantageous when space is limited.
However, it should be noted that air-cooled chillers may be slightly less efficient than water-cooled systems in heat dissipation efficiency, especially in high-temperature environments. In addition, since air cooling requires the use of fans, noise and vibration may occur. Therefore, when selecting cooling equipment, it is necessary to comprehensively consider the advantages and disadvantages based on specific needs and process requirements, and weigh various factors.
Q1: Could you help us to recommend the model for our project?
A1: Yes, we have engineer to check the details and make the scheme for you. Based on the following:
1)Cooling capacity;
2)chilled water inlet and outlet temperature
3)chilled water flow
4) Refrigerant;
5) Ambient temperature;
6)Voltage;
7) Be used for what industry?
8)Any other special requirements
Q2: How to ensure your product with good quality?
A2: All our products with CE certificate. And use the well-know brand compressors and refrigeration accessories . All OUMAL Chillers are factory tested under load conditions to ensure good quality and easy installation for users.
Q3: What's the warranty?
A3: 15 months warranty for free if confirmed by both side damage in the quality reason.
Q4: What's your payment term?
A4: We accept T/T, LC, Western Union, etc. Normally, 30% deposit for production, 70% balance before shipment.
Q5: Are you a manufacturer?
A5: Yes, we have more than 15 years in water chiller business. Also have patent on the water chiller appearance .
The control box design make the unit safety and stably.
Q6: How can i Place an order
A6: Send inquiry to us or Call us.