Customization: | Available |
---|---|
After-sales Service: | 7 X 24 Hours |
Warranty: | 15 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
A water cooling chiller plant is a system used to cool industrial processes and equipment by circulating chilled water. In the context of PET bottle blowing machines, water cooling chiller plants are commonly used to regulate the temperature of the molds during the bottle production process.
Water cooling chiller also called water cooled chiller, water to water cooled chiller, water cooled packaged chiller.
Here are some key considerations for a water cooling chiller plant for PET bottle blowing machines:
Cooling Capacity: The chiller plant should have sufficient cooling capacity to handle the heat generated during the PET bottle blowing process. The cooling capacity requirement depends on factors such as the machine's output, cycle time, and the size and complexity of the molds.
Temperature Control: Precise temperature control is crucial for achieving consistent bottle quality and preventing defects. The chiller plant should provide accurate temperature control to maintain the desired temperature range of the molds.
Water Quality and Treatment: The water used in the chiller plant should meet certain quality standards to ensure proper cooling and prevent scaling or corrosion. Water treatment equipment, such as filters and water softeners, may be necessary to maintain the water's cleanliness and quality.
Energy Efficiency: Energy-efficient chiller plants can help reduce operational costs. Look for chiller systems with features like variable frequency drives (VFDs) or energy-saving modes that optimize energy consumption based on the cooling demand.
Reliability and Maintenance: The chiller plant should be reliable and durable to minimize downtime and maintenance requirements. Consider the reputation of the manufacturer and the quality of components used in the system. Additionally, easy accessibility for maintenance and serviceability of the chiller plant is essential for efficient operation.
Control and Monitoring: A user-friendly control panel and monitoring system allow operators to easily adjust and monitor the chiller plant's performance. This helps in maintaining the desired temperatures and identifying any issues or abnormalities in the cooling process.
Safety Features: Ensure that the chiller plant has necessary safety features like temperature and pressure sensors, alarms, and automatic shutdown mechanisms to protect the equipment and prevent any accidents or damage.
It is important to consult with a professional technician or engineer to assess your specific requirements and select the most suitable water cooling chiller plant for your PET bottle blowing machine.
The main parts of a box-type water-cooled water chiller typically include:
Compressor: The compressor is responsible for compressing the refrigerant vapor, raising its temperature and pressure.
Condenser: The condenser is a heat exchanger where the high-pressure, high-temperature refrigerant vapor releases heat and condenses into a liquid state when it comes into contact with the cool water circulating through the condenser.
Evaporator: The evaporator is another heat exchanger where the liquid refrigerant absorbs heat from the water or air being cooled. As the refrigerant absorbs this heat, it evaporates into a vapor state.
Expansion Valve: The expansion valve regulates the flow of refrigerant from the high-pressure side to the low-pressure side of the system, creating a pressure drop and allowing the refrigerant to evaporate and absorb heat efficiently in the evaporator.
Water Circulation System: The water circulation system includes pumps, pipes, and a water reservoir or cooling tower (if required) to constantly circulate the chilled water through the chiller's condenser and evaporator, facilitating the heat exchange process.
Control Panel: The control panel houses the electrical controls, sensors, and display interface for monitoring and controlling the chiller's operation. It allows users to set and adjust temperature parameters, monitor system performance, and ensure safe and efficient operation.
These components work together to extract heat from the water or air being cooled and transfer it to the surrounding environment through the water-cooled condenser. This process helps maintain the desired temperature of the chilled water or cooling medium in various industrial applications.
Specifications:
Model Item |
OMC-3W | OMC-5W | OMC-8W | OMC-10W | OMC-12W | OMC-15W | OMC-20W | OMC-25W | OMC-30W | OMC-40W | OMC-50W | ||
Cooling Capacity | KW | 9 | 15 | 24 | 30 | 36 | 45 | 60 | 75 | 90 | 120 | 150 | |
Kcal/h | 7740 | 12900 | 20640 | 25800 | 30960 | 38700 | 51600 | 64500 | 77400 | 103200 | 129000 | ||
Ton | 2.5 | 4.2 | 6.8 | 8.5 | 10.2 | 12.8 | 17.0 | 21.3 | 25.5 | 34.1 | 42.6 | ||
Btu/h | 30716 | 51194 | 81911 | 102389 | 122866 | 153583 | 204778 | 255973 | 307167 | 409556 | 511945 | ||
Input power | KW | 2.62 | 4.5 | 6.75 | 8.25 | 10.2 | 12.75 | 17.2 | 20.95 | 26.5 | 34 | 43 | |
Power supply | 3 PH-380V 50Hz | ||||||||||||
Temperature Range | ºC | 5-35 | |||||||||||
Refrigerant | Type | R22(R407C/R410A/R134A) | |||||||||||
Compressor | Control Mode | Capillary | Expansion Valve | ||||||||||
Type | Scroll type / Piston Type | ||||||||||||
Power | KW | 2.25 | 3.75 | 6 | 7.5 | 9 | 11.25 | 15 | 18.75 | 22.5 | 30 | 37.5 | |
Chilled water | Tank Volume | L | 60 | 70 | 150 | 180 | 240 | 300 | 400 | 400 | 540 | 630 | 700 |
Tank Material | SUS304 Stainless Steel | ||||||||||||
Pipe Diameter | 1-1/2" | 1-1/2" | 1-1/2" | 1-1/2" | 1-1/2" | 2" | 2" | 2-1/2" | 2-1/2" | 3" | 3" | ||
Pump | Lift | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | |
Power | 0.37 | 0.75 | 0.75 | 0.75 | 1.2 | 1.5 | 2.2 | 2.2 | 4 | 4 | 5.5 | ||
Evaporator | Type | Tank with coil(Shell and tube) | |||||||||||
Chilled water flow | m³/h | 1.5 | 2.6 | 4.1 | 5.2 | 6.2 | 7.7 | 10.3 | 12.9 | 15.5 | 20.6 | 25.8 | |
Condenser | Type | Shell and tube | |||||||||||
Cooling water flow | m³/h | 1.95 | 3.37 | 5.26 | 6.62 | 7.95 | 9.89 | 13.26 | 16.50 | 20.06 | 26.45 | 33.20 | |
Safety Protection | Compressor overheating protection, over-current protection, high and low pressure protection, over-temperature protection, flow protection,reversed and lacking phase protection, exhaust overheating protection. | ||||||||||||
Dimension | Length | mm | 850 | 900 | 1100 | 1250 | 1300 | 1450 | 1600 | 1620 | 1650 | 1900 | 2000 |
Width | mm | 500 | 500 | 680 | 600 | 600 | 780 | 850 | 850 | 850 | 1000 | 1000 | |
Height | mm | 880 | 980 | 1300 | 1300 | 1350 | 1350 | 1460 | 1480 | 1500 | 1650 | 1700 | |
Weight | KG | 130 | 160 | 300 | 450 | 680 | 740 | 820 | 900 | 1100 | 1300 | 1500 |
Water-cooled water chillers have a wide range of applications in various industries and processes where cooling is required. Some common applications include:
HVAC Systems: Water-cooled chillers are commonly used in building air conditioning systems to provide cooling for offices, commercial spaces, and residential complexes.
Industrial Processes: Water-cooled chillers are extensively used in industrial processes such as plastic injection molding, metalworking, chemical manufacturing, pharmaceutical production, food and beverage processing, and data centers. They help control the temperature of equipment and materials, ensuring efficient operation and product quality.
Power Generation: Water-cooled chillers are often employed in power plants to cool turbines, generators, and other equipment for efficient and reliable operation of the power generation process.
Refrigeration Systems: Water-cooled chillers are used in refrigeration systems for preserving perishable goods, such as in cold storage warehouses, food processing facilities, and supermarkets.
Medical and Laboratory Equipment: Water-cooled chillers are utilized to cool medical imaging machines, laboratory equipment, research instruments, and other precision equipment that require precise and stable temperature control.
Printing and Packaging: Water-cooled chillers play a vital role in maintaining the temperature of printing presses and packaging equipment, ensuring optimal performance and quality of printed materials.
Plastics and Rubber Industry: In manufacturing processes such as extrusion, blow molding, and thermoforming, water-cooled chillers are used to cool molds and maintain consistent temperature control during the production of plastic and rubber products.
Chemical and Petrochemical Industry: Water-cooled chillers are widely used in the chemical and petrochemical industry to cool reaction vessels, chemical reactors, and other equipment involved in chemical processes.
These are just a few examples of the many applications where water-cooled water chillers are employed. Their versatility, efficiency, and reliable cooling capabilities make them an essential component in various industries and processes.
Q1: Could you help us to recommend the model for our project?
A1: Yes, we have engineer to check the details and make the scheme for you. Based on the following:
1)Cooling capacity;
2)chilled water inlet and outlet temperature
3)chilled water flow
4) Refrigerant;
5) Ambient temperature;
6)Voltage;
7) Be used for what industry?
8)Any other special requirements
Q2: How to ensure your product with good quality?
A2: All our products with CE certificate. And use the well-know brand compressors and refrigeration accessories . All OUMAL Chillers are factory tested under load conditions to ensure good quality and easy installation for users.
Q3: What's the warranty?
A3: 15 months warranty for free if confirmed by both side damage in the quality reason.
Q4: What's your payment term?
A4: We accept T/T, LC, Western Union, etc. Normally, 30% deposit for production, 70% balance before shipment.
Q5: Are you a manufacturer?
A5: Yes, we have more than 15 years in water chiller business. Also have patent on the water chiller appearance .
The control box design make the unit safety and stably.
Q6: How can i Place an order
A6: Send inquiry to us or Call us.